GLC DATA Continued

 

Alternator

Engine

 

 

 

 

 

Output

 

 

 

 

GLC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Model

Leads/

Fuel

Size

KW

Phase

Voltage

VAC

VAC

FLA

115%

Circuit

C.T.

Wire Size

 

Winding

Type

Rated

Config

(L - L)

(L - N)

FLA

Breaker

Ratio

(QTY) AWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC100

UCI274E

4/06

Nat Gas

GM/8.1L

84

1

Series

240

120

350

403

400

400:5

(2) #4/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC100

UCI274E

12/311

Nat Gas

GM/8.1L

86

3

// WYE

208

120

298

343

350

400:5

(1) #3/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC100

UCI274E

12/311

Nat Gas

GM/8.1L

86

3

// WYE

220

127

282

324

350

400:5

(1) #3/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC100

UCI274E

12/311

Nat Gas

GM/8.1L

86

3

Series/

240

120

259

297

300

300:5

(1) #2/0

 

 

 

 

 

 

 

Delta

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC100

UCI274E

12/311

Nat Gas

GM/8.1L

87

3

// WYE

240

139

262

301

300

300:5

(1) #2/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC100

UCI274E

12/311

Nat Gas

GM/8.1L

86

3

Series

380

220

163

188

200

200:5

(1) #1

 

 

 

 

 

 

 

Wye

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC100

UCI274E

12/311

Nat Gas

 

 

3

 

416

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC100

UCI274E

12/311

Nat Gas

GM/8.1L

87

3

Series

480

277

131

150

150

150:5

(1) #4

 

 

 

 

 

 

 

Wye

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC100

UCI274E

4/06

LPG

GM/8.1L

97

1

Series

240

120

404

465

500

500:5

(2) #1/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC100

UCI274E

12/311

LPG

GM/8.1L

99

3

// WYE

208

120

344

395

400

400:5

(2) #4/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC100

UCI274E

12/311

LPG

GM/8.1L

99

3

// WYE

220

127

325

373

400

400:5

(2) #4/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC100

UCI274E

12/311

LPG

GM/8.1L

99

3

Series/

240

120

298

342

350

400:5

(1) #3/0

 

 

 

 

 

 

 

Delta

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC100

UCI274E

12/311

LPG

GM/8.1L

100

3

// WYE

240

139

301

346

350

400:5

(1) #3/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC100

UCI274E

12/311

LPG

GM/8.1L

98

3

Series

380

220

186

214

225

250:5

(1) #1

 

 

 

 

 

 

 

Wye

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC100

UCI274E

12/311

LPG

 

 

3

 

416

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC100

UCI274E

12/311

LPG

GM/8.1L

100

3

Series

480

277

150

173

175

200:5

(1) #1

 

 

 

 

 

 

 

Wye

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC80

UCI224G

4/06

Nat Gas

GM/8.1L

75

1

Series

240

120

313

359

400

400:5

(2) #4/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC80

UCI274C

12/311

Nat Gas

GM/8.1L

80

3

// WYE

208

120

278

319

350

400:5

(1) #3/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC80

UCI274C

12/311

Nat Gas

GM/8.1L

80

3

// WYE

220

127

262

302

300

300:5

(1) #2/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC80

UCI274C

12/311

Nat Gas

GM/8.1L

80

3

Series/

240

120

241

277

300

300:5

(1) #2/0

 

 

 

 

 

 

 

Delta

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC80

UCI274C

12/311

Nat Gas

GM/8.1L

80

3

// WYE

240

139

241

277

300

300:5

(1) #2/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC80

UCI274C

12/311

Nat Gas

GM/8.1L

80

3

Series

380

220

152

175

175

200:5

(1) #1

 

 

 

 

 

 

 

Wye

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC80

UCI274C

12/311

Nat Gas

 

 

3

 

416

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC80

UCI274C

12/311

Nat Gas

GM/8.1L

80

3

Series

480

277

120

138

150

150:5

(1) #4

 

 

 

 

 

 

 

Wye

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC80

UCI224G

4/06

LPG

GM/8.1L

75

1

Series

240

120

313

359

400

400:5

(2) #4/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC80

UCI274C

12/311

LPG

GM/8.1L

80

3

// WYE

208

120

278

319

350

400:5

(1) #3/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC80

UCI274C

12/311

LPG

GM/8.1L

80

3

// WYE

220

127

262

302

300

300:5

(1) #2/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC80

UCI274C

12/311

LPG

GM/8.1L

80

3

Series/

240

120

241

277

300

300:5

(1) #2/0

 

 

 

 

 

 

 

Delta

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC80

UCI274C

12/311

LPG

GM/8.1L

80

3

// WYE

240

139

241

277

300

300:5

(1) #2/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC80

UCI274C

12/311

LPG

GM/8.1L

80

3

Series

380

220

152

175

175

200:5

(1) #1

 

 

 

 

 

 

 

Wye

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC80

UCI274C

12/311

LPG

 

 

3

 

416

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLC80

UCI274C

12/311

LPG

GM/8.1L

80

3

Series

480

277

120

138

150

150:5

(1) #4

 

 

 

 

 

 

 

Wye

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MN2408

Series GLC A-5

Image 81
Contents GLC Generator California Proposition 65 Warning Table of Contents Appendix a Generator AC Metering Engine Parameter DisplayRead This Manual Thoroughly Section Product Safety InformationOperation SymbolsOperation Warning Statements Burn Installation Maintenance Product Safety Information MN2408 Limited Warranty Warranty PeriodLabor Parts General Information MN2408 Site Planning Installation GuidelinesEngine Cooling System Controls and Transfer SwitchExhaust System Room AirFoundation Design Foundation Checklist Setting The Genset On An Existing Concrete Floor SlabVibration Isolators Approximate Weight vs. kW Output Weight Of The GensetCalculate Soil Bearing Load SBL Capacity Designing An Isolated FoundationApproximate Load Bearing Capacities of Various Soil Types Typical Foundation InstallationSystem Placement Exhaust System Exhaust ChecklistMulti-Engine Installations Level Of AttenuationExhaust System Calculations Exhaust Piping Radiator Cooling Cooling System Cooling System ChecklistHeat Exchanger Cooling System DeterminationCooling System Design Engine Mounted Radiator Cooling Remote Radiator Cooling Hot Well Installations11 Valves & Fittings and Fluid Flow in Pipe Other Considerations 13 Coolant Mixture Wind Barrier Air System Air System ChecklistEngine Crankcase Ventilation Transfer Switch Location Transfer Switch Transfer Switch ChecklistBattery Location Battery Starting SystemBattery Cables Battery ChargerGeneral Information MN2408 Generator Lifting When the Generator is installed outdoorsGenerator Mounting Mounting DimensionsVentilation Test Secure the GeneratorHot Exhaust Gasses Backpressure must not exceed 20 of water columnGuidelines for Exhaust System Page Fuel Connections Fuel Consumption Natural and LPGGeneral Considerations Example Determining Pipe Size for Natural Gas Natural Gas ConnectionsNatural Gas Flow Rate Cubic Feet per Hour per Pipe Length LP Gas Flow Rate Cubic Feet per Hour per Pipe Length Example Determining Pipe Size for LPGRating Transfer Switch ConsiderationsThree Phase WYE and Delta Connections Battery Charger Considerations General Wiring ConsiderationsFrame Ground Connection Page Post Installation Checks Recommended Engine Oil and Battery TypeGLC100 GLC125Post Installation Checks On when the OFF Switch is used to stop the engine Run SwitchOperator Control Panel Digital Engine Controller Only Programming KeysOperator Control Panel Manual Start/StopAutomatic Start/Stop Automatic Mains Failure AMF Automatic Fault ShutdownUtility Power Restored Utility Power Failure ConditionsUtility Normal Condition Load Test Push-button OperationNo Load Test Engine Controller Inputs & Outputs Analog Faults Such as Fuel Rack Solenoids or electronic governors RunCrank Engine starter motorAction Description Display Comments Are no active faultsFront panel keypad push-button NormalOther time delay functions are Generator KVA Display Phase system not applicableVab Displays the generators output voltage Vbc Displays the generators output voltageBattery Voltage/Engine Speed Navigation Hints Main Menu Loop Voltage Calibration Procedure Repeat for each phase Span CalibrationDisplayed values Displays the type of calibration function Engine Temperature & Oil Pressure CalibrationOil Pressure UsedConfiguration Data Sheet Main Menu Loop Parameters 198 F Alarm Fault Name Input AnalogParameter Setting Volts A-B Battery VoltageEngine Control Connections 10 Analog Operator Control Panel Operator Control Panel Analog Engine Controller Only11 9957N Analog Engine Controller Connections 12 A121H Analog Engine Controller Connections Garretson Model KN Fuel Valve Considerations General ServiceInstallation Engine Section Troubleshooting and MaintenanceGeneral Troubleshooting Guide Problems and SolutionsTroubleshooting Guide Digital Controller Only Troubleshooting Guide Analog Controller Only Verify the adjustments. Replace controller if failedSpeed DIODE, 1N5408 Part numberReplacement Parts GLC GLC125LAMP, #67, 12 Volt Cable Jam Nut Flywheel Housing Magnetic PickupFLA GLC Circuit Breaker & Electrical DataGLC Data 259 300 MN2408 Series GLC A-7 144 150 GLC Wire Size Figure A-2 Customer Interface Connection Diagram MN2408 Series GLC A-11 Figure A-4 Single Phase w/o Breaker Connection Diagram Figure A-5 Single Phase One Breaker Connection Diagram Figure A-6 Single Phase Two Breaker Connection Diagram MN2408 Series GLC A-15 Series GLC MN2408 MN2408 Series GLC A-17 Series GLC MN2408 Figure A-11 Three Phase Connection Diagram Figure A-12 Three Phase Connection Diagram with PMG MN2408 Series GLC A-21 Series GLC MN2408 MN2408 Series GLC A-23 Series GLC MN2408 MN2408 Series GLC A-25 Series GLC MN2408 MN2408 Series GLC A-27 Figure A-20 Control Box Connections with MEC2 Controller Figure A-21 Engine Wiring, Woodward 4.3L GM Figure A-22 Engine Wiring, Woodward 5.7L GM Figure A-23 Engine Wiring, Woodward 8.1L GM Series GLC MN2408 Name Address Phone Model Number Job Number PowerStandby Continuous No LoadSwitch Adjust the AC voltage to match the normal sourceAre legible Proper belt alignment and tensionsBaldor District Offices Baldor Electric Company MN2408 04 FAR200