Maytag MED5591TQ1 Vent system chart 0 ft 0 m to 10 ft 3.0 m, No, Length of flexible metal vent

Page 17

Vent system chart - 0 ft (0 m) to 10 ft (3.0 m)

_ssss/_

 

 

 

 

 

No. of

0

ft

1-.5 ft

6-10 ft

Length of flexible metal vent

turns or

(0

m)

(0.3-1.5 m)

(1.8-3.0

m)

elbows

 

 

 

 

 

3.Run vent to dryer location. Use the straightest path possible. See "Determine vent path" in "Plan Vent System." Avoid 90 ° turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior of the vent to secure vent.

0

120

ft

105

 

ft

90 ft

 

 

(36.6

m)

(32.0

m)

(27.4

m)

1

110

ft

95

ft

 

80 ft

 

 

(33.5

m)

(29.0

m)

(24.4

m)

2

100

ft

85

ft

 

70 ft

 

 

(30.5

m)

(25.9

m)

(21.3

m)

3

9O ff

 

75

ft

 

6O ft

 

 

(27.4

m)

(22.9

m)

(18.3

m)

4

8O ff

 

65

ft

 

5O ft

 

 

(24.4

m)

(19.8

m)

(15.2

m)

5

7O ff

 

55

ft

 

4O ft

 

 

(21.3

m)

(16.8

m)

(12.2

m)

Vent system chart - 11 ft (3.4 m) to 25 ft (7.6 m)

No.

of

11-15

ft

16-20

ft

21-25

ft

turns

or

(3.4-4.6 m)

(4.9-6.1 m)

(6.4-7.6 m)

elbows

 

 

 

 

 

 

 

0

 

75 ff

 

60

ff

 

45 ff

 

 

 

(22.9

m)

(18.3

m)

(13.7

m)

1

 

65 fl

 

50

ff

 

35 ff

 

 

 

(19.8

m)

(15.2

m)

(10.7

m)

2

 

55 ff

 

40

ff

 

25 ff

 

 

 

(16.8

m)

(12.2

m)

(7.6

m)

3

 

45ff

 

30ff

 

 

15ff

 

 

 

(13.7

m)

(9.1

 

m)

(4.6

m)

4

 

35 ff

 

20

ff

 

5 ff

 

 

 

(10.7

m)

(6.1

 

m)

(1.5

m)

5

 

25fl

 

10ff

 

 

Off

 

 

 

(7.6

m)

(3.0

 

m)

(0 m)

Length of rigid metal vent

Length of flexible metal vent

Length of rigid metal vent

Excessive Weight Hazard

Use two or more people to move and install dryer.

Failure to do so can result in back or other injury.

1.[b protect the floor, use a large, flat piece of cardboard from the dryer carton. Place cardboard under the entire back side of the dryer.

2.Firmly grasp the body of the dryer (not the top or console panel). Gently lay the dryer on the cardboard. See illustration.

3.Examine the leveling legs. Find the diamond marking.

4.Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the diamond marking is no longer visible.

5.Place a carton corner post from dryer packaging under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent.

1.

Using a 4"

(10.2

cm) clamp,

connect

vent

to

exhaust

outlet in

dryen

If connecting

to

 

existing vent, make sure the vent is clean. [he dryer vent must fit over the dryer exhaust

 

outlet

and

inside

the exhaust

hood.

Check

that

the

vent

is secured

to exhaust hood

with a

 

4" (10.2

cm) clamp.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Move

dryer

into

its final

location.

Do

not

crush

or

kink

vent.

 

 

 

 

3.

(On

gas

models)

Check

that

there

are

no

kinks

in the

flexible

gas

line.

 

4.

Once

the exhaust

vent

connection

is made,

remove

 

the

corner

posts

and cardboard.

 

1.Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood.

2.Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.

Image 17
Contents W10088776A Secheuse Electrique Avec Conduit DevacuationTable DES Matieres Table of Contents IndiceOut Do not use Dryer SafetyWhen the dryer is Used Near Installation Clearances Compound For installingVent clamps Caulking gunMobile Home Installations Installation Requirements110cm 5cmIf connecting by direct wire If using a power supply cordIf your outlet looks like this Wirrceptacl lO-30RIt is your responsibility Do not use an extension cordAB C D Nema If your Home has You will Go to Section Connecting toWire receptacle Nfma type 14-30R Prong plug Wire connection Power Supply CordShown Wire connection Direct Wire Neutral ground wire Fxternal ground conductor screw If this is a new vent system Vent material If using awl existing vent systemRigid metal vent ElbowsLouwred hood styli Box hood style Recommended exhaust installations10.2 cm Special provisions for mobile home installations Alternate installations for close clearancesDetermine vent path VentNo. Vent system chart 0 ft 0 m to 10 ft 3.0 mLength of flexible metal vent CheckCanada U.S.AOr fire Dryer USEHow Automatic Drying Works To stop your dryerDryer Care Every Load CleaningRack Dry Temp TimeAs Needed Cleaning For direct-wired dryersMoving care For power supply cord-connected dryers From Inside the Dryer CabinetDo not use a metal foil vent TroubleshootingUse a heavy metal vent Do not use a plastic vent Has an air dry cycle been selected? Is the dryer located in a closet?Lint on load Is the lint screen clogged? Is the dryer being used for the first time?If you need replacement parts Ii %iii!i Maytag Corporation Major Appliance WarrantyPage Ii%iii!i!27 Seguridad DE LA SecadoraTijeras para lata instalaciones Del nuevo ducto de escape QueNivel Abrazaderas para ductoPiezas necesarias Patas niveladorasEspacios para la instalaci6n 27%Conexi6n elctrica Ponerse en contacto con un instalador el6ctrico calificadoAs instalaciones en casas rodantes necesitan Cntacto de 3 alambrs f 10-30R Siempleauncable de suministro el6ctricoSi el contacto de pared luce como 6ste Instale el protector de cables Incendio o choque electricoConector Del conducto Removible IZI¸IZILElctrica Opciones para la conexi6nConductordetierraexternoAprieteeltornillo £ Hilo neutlo diGpuesta a tiGna Ld!Y Si usa un sistema de ventilaci6n existente Peligro de IncendioDucto de escape de metal rigido Ducto descape c/rnetal pesado c/4 10,2 crn10,2 cm BienMdjorPara espacios limitados Seleccione FlexibleDe ventilaci6n InstalacionesPies 105 pies 90 pies 36,6 m 32,0 m 27,4 m Peligro de Peso Excesivo DevueltasDel ducto SJ,a¢, oY 6 , 5eaioa Ciclo de Aire USO DE LA SecadoraPara volver a poner en marcha su secadora Para detener y volver a poner en marchaEstante Temp TiempoDel ducto de escape Limpieza de cada cargaLimpieza peri6dica Cuidado para las vacaciones La secadora no funciona Solucion DE ProblemasEl temporizador no avanza notablemente Demasiado largos, o la carga est demasiado calienteEslJ la secadora ubicada en un armario? Ropa arrugadaPelusa en la ropa Est obstruido el filtro de pelusa? Attn CAR Center Ayuda O Servicio TecnicoSi necesita piezas de repuesto Exclusion DE Garantas IMPLiCITAS Limitacin DE Recursos Garanta Limitada DE UN AiioPage Votre scurit et celle des autres est tres importante Securite DE LA SecheuseIncendie Ou une explosion Fabriques Secheuse Les Articles Contamines Par desIorsque La secheuse UtiiiseeIid de nivellement Instructions DinstallationPiices fournies Linstallation dans une maison mobile exige Dimensions de la scheuseCest Iutilisateur quincombe la responsabilit de Instructions DE Liaison a LA TerreBonMeilleur CZmduit dvacuation en mtal Iourd de 4 10,2 cmConduit mtallique flexible Bride deserrage Installations dvacuation recommandesRigide ou souple Dterminer Iitinraire dacheminement du conduit Autres installations o le dgagement est rduitTableaux des systmes dvacuation TableauNombre De change Ments de Direction Du conduit DirectionDvacuation mtallique HaH Si la scheuse ne dmarre pas, vrifier ce qui suit Us ts, @ Arrt et remise en marche Fonctionnement du programme de schage automatiqueNettoyage au besoin Entretien DE LA SecheuseNettoyage avant chaque charge O1tHl Precautions prendre avant un dmnagementIntrieur de la caisse de la scheuse Iintrieur du conduit dvacuationNe pas utiliser un conduit devacuation en feuilie de metal Ne pas utiliser un conduit devacuation en piastiqueCharges froiss6es Charpie sur la chargeTaches sur la charge ou sur le tambour Pour plus dassistance Assistance OU ServiceSi vous avez besoin de pices de rechange Garantie Limitce DE UN AN Garantie DES Gros Appareils Menagers Maytag CorporationW10088776A