Middleby Marshall Model PS536 Electrical specifications for electric ovens per oven cavity

Page 5

SECTION1-DESCRIPTION

Table 1-3: Electrical specifications for electric ovens (per oven cavity)

Main Blower

Control

 

 

 

Current Draw

k W

 

 

Voltage

Circuit Voltage

Phase

Freq.

L1

L2

L3

N

Rating

Poles

Wires

208V

120V conv. speed control,

3 Ph

60 Hz

50A

50A

50A

--

16.0 kW

4 Pole

4 Wire

 

drive motor, contactor,

 

 

 

 

 

 

at 208V

 

(3 hot, 1 gnd)

 

& temp. control; all others 208V

 

 

 

 

 

 

 

 

 

230V

120V conv. speed control,

3 Ph

60 Hz

45A

45A

45A

--

16.0 kW

4 Pole

4 Wire

 

drive motor, contactor,

 

 

 

 

 

 

at 230V

 

(3 hot, 1 gnd)

 

& temp. control; all others 230V

 

 

 

 

 

 

 

 

 

380V *

120V conv. speed control,

3 Ph

50 Hz

25A

25A

28A

5A

16.0 kW

4 Pole

5 Wire (3 hot,

 

drive motor, contactor,

 

 

 

 

 

 

at 380V

 

1 neutral, 1 gnd)

&temp. control; 380V heating elements; all others 240V

* 380V model is not approved by or .

ENGLISH

Table 1-4: Electrical specifications for gas ovens (per oven cavity)

Main Blower

Control

 

 

Current

 

 

Voltage

Circuit Voltage

Phase

Freq.

Draw

Poles

Wires

208/240V

120V conv. speed control,

1 Ph

60 Hz

6A

3 Pole

4 Wire (2 hot, 1 neut, 1 gnd)

 

drive motor, contactor,

 

 

 

 

 

 

& temp. control; all others

 

 

 

 

 

 

as per line (208/240V)

 

 

 

 

 

Table 1-5: Gas orifice and pressure specifications (per oven cavity)

 

 

 

 

Orifice (Manifold)

Gas Type

Main Orifice I.D.

Pilot Orifice I.D.

Supply (Inlet) Pressure

Pressure

Natural

0.0935” (2.3749mm, #42 drill)

0.018” (0.46mm)

4-7” W.C. (9.95-17.4mbar) *

3.5” W.C. (8.7mbar)

 

 

 

 

 

Propane

0.0520” (1.3208mm, #55 drill)

0.018” (0.46mm)

11-14” W.C. (27.4-34.9mbar) *

10.5” W.C. (24.9mbar)

*The gas supply pressures shown are for ovens installed in North America. The required gas supply pressures of other locations are dependent on the local gas type and on all applicable local codes.

IMPORTANT

Additional electrical information is provided on the oven's serial plate, and on the wiring diagram inside the machinery compartment.

5

Image 5
Contents PS536 Gas and Electric Ovens English Table of Contents Description III. Oven SpecificationsOven Uses II. Oven Components see FigureElectrical specifications for electric ovens per oven cavity Installation Installation Kit Installation KIT see FigureRequirements II. Ventilation SystemRecommendations Other ventilation concernsTop panel and base pad installation III. AssemblyStacking Restraint Cable InstallationAssembling and tensioning the conveyor Conveyor Installation10 Conveyor placement Final AssemblyVII. GAS Supply DuringpressuretestingnoteoneofthefollowingVI. Electrical Supply Gas Conversion Gas Utility Rough-In RecommendationsLocation and Description of Controls OperationII. Normal Operation STEP-BY-STEP If the oven uses this Digital Temperature ControllerDailystartupprocedure For DailyshutdownprocedureLight III. Quick Reference Digital Temperature ControllersActual SP LockOvertemp Symptom IV. Quick Reference TroubleshootingMaintenance Daily MaintenanceSplit Belt Disassembly and Cleaning II. Maintenance MonthlyIII. Maintenance Every 3 Months Disassembling the drive shaft KEY Spare Parts KIT Available sepa- rately. See Figure IV. Maintenance Every 6 MonthsBlower Belt Lubricating the Blower Fan BearingsWiring diagram, PS536 Gas Oven 208/230V, 60 Hz, 1 Ph Electrical Wiring DiagramsWiring diagram, PS536 Electric Oven 208/230V, 60 Hz, 3 Ph Wiring diagram, PS536 Electric Oven 380V, 50 Hz, 3 Ph English Français Fours électriques et à gaz, modèle PS536 Avertissement Fonctionnement Table DES MatièresEntretien Schémas DE CâblageIII. Spécifications DU Four Utilisations DU FourII. Composants DU Four Figure Neut., 1 masse Mise EN Garde Trousse d’installation Trousse D’INSTALLATION FigureAutres considérations pour la ventilation RecommandationsII. Système DE Ventilation Panneau supérieur et plaque de pose III. AssemblageSuperposition Installation du câble de retenueAssemblage et ajustement de tension du Transporteur Installation du transporteurAssemblage Final 10 Placement du transporteurDURANTL’ESSAIDEPRESSION,NOTEZCEQUISUIT VI. Alimentation EN ÉlectricitéVII. Alimentation EN GAZ 14 Installation du tuyau à gaz flexible Fonctionnement Emplacement ET Description DES CommandesProcédurequotidiennedemiseenmarche II. Fonctionnement Normal PAS-À-PASPROCÉDUREQUOTIDIENNEDEMISEÀL’ARRÊT AttendezAffichage du Temp » Lock »« Overtemp » Symptôme IV. Consultation Rapide Résolution DE ProblèmesAvertissement EntretienMise EN Garde RemarqueIII. Entretien Trimestriel II. Entretien MensuelDémontage de l’arbre d’entraînement IV. Entretien Semestriel Schéma de câblage, Four à gaz PS536 208/230 V, 60 Hz, 1 Ph Schémas DE CâblageSchémas DE Câblage Schéma de câblage, Four électrique PS536 380 V, 50 Hz, 3 Ph Anglais Français Espagnol Hornos de Gas y Eléctricos PS536 Aviso Índice SECCIÓN5-DIAGRAMASDELCABLEADOELÉCTRICOSección 3 Operación Sección 4 MantenimientoIII. Especificaciones DEL Horno SECCIÓN1DESCRIPCIÓNImportante Precaución Sección 2 InstalaciónJuego de Instalación Juego DE Instalación ver FiguraII. Sistema DE Ventilación Otros problemas de ventilaciónRequisitos RecomendacionesConjunto del panel superior y cojín de base III. EnsambladoPara hornos sencillos, pase al apartado C, Instalación del ApiladoCable de sujeción. Para hornos dobles o triples, continúe Con el paso 1 descrito a continuaciónFigura 2-8 Instalación y tensión del transportador Instalación del TransportadorFigura 2-10 Colocación del transportador Ensamblado FinalDurantelaspruebasdepresiónobservelosiguiente VI. Suministro EléctricoVII. Suministro DE GAS Precaución Conversión Según el Tipo de Gas ConexiónUbicación Y Descripción DE LOS Controles Sección 3 OperaciónProcedimientodiariodeencendido II. Operaciones Normales Paso a PasoSi el horno usa un controlador digital de la temperatura Procedimientodiariodeapagado ImportanteIII. Referencia Rápida Controlador Digital DE Temperatura LuzTemp LockSíntoma IV. Referencia Rápida Diagnóstico DE AveríasAviso SECCIÓN4-MANTENIMIENTONota Mantenimiento DiarioIII. Mantenimiento Trimestral II. Mantenimiento MensualFigura 4-5 Desensamble del eje impulsor Figura 4-6 Acceso al panel posterior IV. Mantenimiento SemestralSolamente Para LOS Hornos DE Banda Doble Sección 5 Diagramas DEL Cableado EléctricoSección 5 Diagramas DEL Cableado Eléctrico Contactor Fases English Français