Acer Altos R710 manual Error Beep Codes Provided by Acer Management Modules

Models: Altos R710

1 214
Download 214 pages 48.28 Kb
Page 169
Image 169

157

Acer Management Modules provide the following additional beep codes.

Error Beep Codes Provided by Acer® Management Modules

Beep Code

Reason for the beeps and action to take

 

 

1

Control panel CMOS clear has been initiated.

 

 

1-5-1-1

Processor failure. Reseat or replace the failed processor.

 

 

1-5-2-1

No processor is installed or the CPU 1 socket is empty.

 

Reseat or replace the failed processor.

 

 

1-5-2-3

Processor configuration error or CPU 1 socket is empty.

 

Reseat or replace the failed processor. In a two-processor

 

system, make sure the processors are identical.

 

 

1-5-2-4

Front-side bus selects configuration error.

 

 

1-5-4-2

DC power unexpectedly lost.

 

 

1-5-4-3

Chipset control failure.

 

 

1-5-4-4

Power control failure.

 

 