Appendix C: RAID Configuration

180

Appendix C: RAID Configuration

Note: In the Hot Spare field, if you change settings, you will see the following messages. Press the DELETE key to ignore it.

WARNING: Data on drive will be LOST!

Press DELETE if data loss OK or any other key to cancel.

5 Press ESC, then select <Save changes then exit this menu>.

RAID Volume Initialization

After you create RAID volume and save the changes, the disk controller will initialize RAID volume automatically. As LSI Logic 20320-R/22320-R can support background initialization, you don°¶t have to wait for the initialization to complete. Now, you can exit LSI Logic Configuration Utility.

Exit and Restart the server

1Press ESC, then select <Exit the Configuration Utility>. Then, you will see a [Global properties saved. Hit any key to reboot.] message.

2Press a key to reboot system.

MegaRAID Configuration Utility

Turn on the system power. When prompted, press <Ctrl> + <M> to enter the MegaRAID Configuration Utility. After entering the MegaRAID Configuration Utility, you will see the Management Menu on the screen.

Load RAID Card Default Setting

1Select Objects from Management menu.

2Select Adapter from Objects. The adapter setting will be shown on the screen. You can change the setting from this menu.

3Select Factory Default and YES to load the default settings.

4Press <Ctrl> + <Alt> + <Del> to reboot the server.