Alcatel-Lucent 6600 manual Setting the Capacitor Detection Method

Models: 6600

1 144
Download 144 pages 57.88 Kb
Page 104
Image 104

Configuring Power over Ethernet Parameters

Installing and Managing Power over Ethernet (PoE)

 

 

 

 

Setting the Capacitor Detection Method

By default, the PowerDsine capacitor detection method is disabled on the OmniSwitch 6600-P24. To enable it use the lanpower capacitor-detectioncommand by entering lanpower capacitor-detectionfollowed by the slot number of the OmniSwitch 6600-P24 and enable.

For example, to enable the capacitor detection method on the OS6600-P24 with slot number 2 enter:

-> lanpower capacitor-detection 2 enable

To disable it use the lanpower capacitor-detectioncommand by entering lanpower capacitor-detectionfollowed by the slot number of the OS6600-P24 and disable.

For example, to disable the capacitor detection method on the OS6600-P24 with slot number 2 enter:

-> lanpower capacitor-detection 2 disable

Note. The capacitive detection method should only be enabled support legacy IP phones only—this feature is not compatible with IEEE specification 802.3af. Please contact your Alcatel sales engineer or Customer Support representative to find out which Alcatel IP phones models need capacitive detection enabled.

page 3-8

OmniSwitch 6600 Family Hardware Users Guide September 2006

Page 104
Image 104
Alcatel-Lucent 6600 manual Setting the Capacitor Detection Method, Lanpower capacitor-detection 2 disable