OmniSwitch 6600 Family Chassis and Hardware Components

Temperature Management

 

 

 

 

Blank Cover Panels

Blank cover panels are provided with your switch and are used to cover empty uplink and stacking module slots, as well as empty backup power supply bays (if applicable). These cover panels play an important role in chassis airflow and temperature management. They also protect the switch’s processor board and other sensitive internal switch components from physical damage by closing off a chassis that is not fully populated.

If your switch is not fully populated with submodules and a redundant power supply, and blank cover panels are not installed over empty slot locations, airflow is adversely affected.

When blank cover panels are missing, air does not take the direct route from the air intake vent, through the chassis, and then out through the fan exhaust vents. Instead, a portion of the airflow is allowed to be drawn in through the front and rear of the chassis. As a result, normal airflow is disrupted and an extra task is placed on the fans to cool the chassis.

Cover panels also provide protection for module processor boards and other sensitive internal switch components by closing off a chassis that is not fully populated.

Because they regulate airflow and help protect internal chassis components, blank cover panels should remain installed over empty module slots and power supply bays at all times.

Missing Cover Panels. Missing cover panels affect airflow by allowing air to be drawn in through the front submodule bays or rear redundant power supply bay. As a result, the direct route from the air intake vent to the fan exhaust vents is dis- rupted.

For optimal airflow and chassis component protec- tion, always install blank cover panels over empty slots and power supply bays.

Air leakage due to

missing submodule cover panels

Air leakage due to

missing redundant power supply panel

Air Intake Vent

Effects of Missing Blank Panels on Chassis Airflow

OmniSwitch 6600 Family Hardware Users Guide September 2006