OmniSwitch 6600 Family Chassis and Hardware Components

Temperature Management

 

 

 

 

Chassis Airflow

The fans pull air from the air intake vent located at the right-hand side of the chassis. The air is directed horizontally through the chassis and past the circuit board and uplink and stacking modules (if installed). Airflow is then exhausted through the fan vents at the left-hand side of the chassis. Refer to the illustra- tions below for more information.

Front of Chassis

Uplink and Stacking Submodules

1. Air Intake. The three chassis fans pull air from the main air intake vent located at the right-hand side of the chassis.

Air Intake Vent

Right Side Air Intake Vent

2.Airflow. The air from the intake vent is directed through the chassis past the

main circuit board and sub- module daughtercards. This airflow provides required cooling for these chassis com- ponents.

3. Air Exhaust. The airflow

 

is exhausted through the fan

 

exhaust vents at the left-hand

 

side of the chassis.

Fan Exhaust Vents

 

Uplink and Stacking Submodules

Front of Chassis

Left Side Fan Exhaust Vents

Important. Maintain a clearance of at least two inches at the left and right sides. Otherwise, airflow may become restricted. Restricted airflow can cause your switch to overheat; overheating can lead to switch failure.

OmniSwitch 6600 Family Hardware Users Guide September 2006

page 2-58

Page 82
Image 82
Alcatel-Lucent 6600 Chassis Airflow, Right Side Air Intake Vent, Left Side Fan Exhaust Vents, Air Exhaust. The airflow