OmniSwitch 6600 Family Chassis and Hardware Components

Viewing Basic Chassis Information

 

 

 

 

Viewing Basic Chassis Information

This section covers the following basic chassis information and monitoring commands:

show hardware info show module

show module long (and show ni) show chassis

show cmm

show session xon-xoff

Important Hardware Status Commands. Additional commands, used to view important hardware status information, are described earlier in this chapter:

For information on viewing primary and backup power supply status, refer to page 2-34.

For information on viewing chassis temperature status, refer to page 2-53.

For information on viewing chassis fan status, refer to page 2-56.

Hardware Information

To view basic hardware information about the switch, enter the show hardware info command at the CLI prompt. This command displays the following information:

CPU type

Flash and RAM memory information

NVRAM battery status

Jumper settings

BootROM and Miniboot versions For example:

-> show hardware info

 

CPU Type

: PowerPC 8245,

Flash Manufacturer

: SanDisk SDCFB-64

Flash size

: 64094208 bytes (61 MB),

RAM Manufacturer

: Kingston,

RAM size

: 134217728 bytes (128 MB),

NVRAM Battery OK

: YES,

Interrupt Boot Jumper

: OFF,

Force UART Defaults Jumper

: ON,

Run Extended Memory Diags Jumper

: OFF,

Spare Jumper

: ON,

BootROM Version

: 5.1.5.115.R02,

Backup Miniboot Version

: 5.1.5.115.R02,

Default Miniboot Version

: 5.1.5.115.R02

OmniSwitch 6600 Family Hardware Users Guide September 2006

page 2-65

Page 89
Image 89