Alcatel-Lucent manual OmniSwitch 6600 Family Rear Panel, Redundant Power Supply Bay

Models: 6600

1 144
Download 144 pages 57.88 Kb
Page 44
Image 44

OmniSwitch 6600 Family Chassis and Hardware Components

Rear Panel

 

 

 

 

Rear Panel

The rear panel of OmniSwitch 6600 Family switches contains the following major components:

Note. Arrangement and location of components vary depending on chassis type.

Factory-installed power supply (all OmniSwitch 6600 Family switches)

Backup power supply bay for optional OS6600-BPS (OS6624, OS6648, OS6600-U24), OS6602-BPS (OS6602-24 and OS6602-48), or OS6602-BPS-DC (OS6602-24 and OS6602-48) power supply

Connector for OS6600-BPS-P PoE backup power supply (OS6600-P24 only)

Power switch (OS6624, OS6648, OS6600-U24, OS6600-P24)

Grounding block for type LCD8-10A-L grounding lug (all OmniSwitch 6600 Family switches)

Power Switch indicates on position; indicates off position.

Product, Safety, and Compliance Information Refer to the “Regulatory Compliance and Safety Information” chapter for detailed information.

Ground Lug Connection

Unpainted area for Type LCD copper lug attach- ment. Refer to page 2-25for more information.

CAUTION: THIS UNIT MAY BE EQUIPPED

!WITH TWO POWER CONNECTIONS. TO REDUCE THE RISK OF ELECTRICAL SHOCK, DISCONNECT BOTH POWER CONNECTIONS BEFORE SERVICING UNIT.

ATTENTION: CET APPAREIL COMPORTE PLUS D'UN CORDON D'ALIMENTATION. AFIN DE PREVENIR LES CHOCS ELECTRIQUES, DEBRANCHE LES DEUX CORDONS D'ALIMENTATION AVANTE DE FAIRE LA REPARATION.

MODEL NO: OS-6648

RATING: 100-240V 50-60Hz, 1.02A

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:

(1)THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND

(2)THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIREMENTS OF THE CANADIAN INTERFERENCE-CAUSING EQUIPMENT REGULATIONS.

CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTS LES EXIGENCES DU REGLEMENT SUR LE MATÉRIEL BROUILLEUR DU CANADA.

Assembled in the US of US and Non-US Components

R

U.S. PATENT NO. 5,394,402

100/115/230 V

50/60 Hz, 2/2/1 A

LISTED

 

 

I.T.E.

 

 

5Z71

 

 

E164613C

R

 

 

geprufte

 

 

Sicherheit

 

LAN PWR PORT

Redundant Power Supply Bay

Slot for optional user-installable OS6600-BPS (OS6624, OS6648, OS6600-U24) or OS6602-BPS (OS6602-24 and OS6602-48) backup power supply. For more information on the backup power supply, including technical specifications and installation instructions, refer to “Backup Power Supply” on page 2-26.

Note: The OS6600-P24 does not have a backup power supply bay. Instead, it has a connector for the OS6600-BPS-P PoE backup power supply.

Power Connector Socket

Type IEC-320-C13. Supports one 10 amp power cord.

It is recommended that you use only Alcatel-provided power cords.

PoE Power Connector

Reserved for use with the PoE backup power supply on the OS6600-P24. See Chapter 3, “Installing and Managing Power over Ethernet (PoE).”

OmniSwitch 6600 Family Rear Panel