Alcatel-Lucent 6600 Monitoring Power over Ethernet via the CLI, Priority Disconnect is Disabled

Models: 6600

1 144
Download 144 pages 57.88 Kb
Page 107
Image 107

Installing and Managing Power over Ethernet (PoE)

Monitoring Power over Ethernet via the CLI

 

 

 

 

Priority Disconnect is Disabled

Reminder. Priority disconnect examples are only applicable when there is inadequate power remaining to power an incoming device.

When priority disconnect is disabled, power will be denied to any incoming PD, regardless of its port priority status (i.e., low, high, and critical) or physical port number (i.e., 1–24).

Monitoring Power over Ethernet via the CLI

To monitor current PoE statistics and settings, use the show lanpower command. The command output displays a list of all current PoE-capable ports, along with the following information for each port:

Maximum power allocated to the port, in milliwatts

Actual power used by the port

Current port status

Power priority status

Power on/off status

Aggregate slot and chassis management information also displays. This information includes:

Maximum watts allocated to the corresponding slot

Amount of power budget remaining that can be allocated for PoE modules

Total amount of power remaining that can be allocated for additional switch functions

OmniSwitch 6600 Family Hardware Users Guide September 2006

page 3-11

Page 107
Image 107
Alcatel-Lucent 6600 manual Monitoring Power over Ethernet via the CLI, Priority Disconnect is Disabled