OPERATOR INPUTS - System Prompts - Configuration - Page
Prompts section that configures the text for the message and states and actuation type associated with each Operator Input. The corresponding actuators can then be changed in the Display Prompts.
OPERATOR MESSAGES - System Prompts - Configuration - Page
Prompts section that configures the two lines of text and DISPLAY MODE for each Operator Message. They are displayed only if their actuator is active and appear during Normal Display as specified by the DISPLAY MODE parameter. They can provide a variety of functions from preemptive critical alarm messages to continuous display of reference information such as what each LED represents.
PEN/COLOR - System Prompts - Configuration - Recorders - Page
Parameter used to specify the pen or color to be used.
POWER UP STATE - System Prompts - Configuration - Operator Inputs - Page
Parameter that specifies what the state of the actuator should be if power to the instrument is removed and reapplied. The choices are: OFF, ON, and SAME. For most applications SAME would be the choice, so the actuator doesn’t change over a power interruption.
PREEMPT - System Prompts - Configuration - Operator Messages - Page
One of the choices for DISPLAY MODE which specifies that the message continuously overrides the display of values.
PREEMPT TO CYCLIC - System Prompts - Configuration - Operator Messages - Page
One of the choices for DISPLAY MODE which specifies that the message overrides the display of values until any key is pressed, after which the message will appear “cyclically”.
PREEMPT TO OFF - System Prompts - Configuration - Operator Messages - Page
One of the choices for DISPLAY MODE which specifies that the message overrides the display of values until any key is pressed, after which it will not appear until the actuator goes inactive then active again.
PRELOAD - System Prompts - Configuration - Totalizers - Page
One of the choices for TOTALIZER TYPE which specifies that the total counts to 999,999,999 and then rolls over to zero. The corresponding preset actuator is true whenever the total is equal to or greater than the TOTALIZER PRESET value. The RESET ACTUATOR resets the total to the TOTALIZER PRESET value.
Print interval
The time between each print cycle, when the pen actuator/cartridge assembly passes over the chart to record trend and other data. The print interval is equal to the value of the chart rotation speed (expressed in hours) expressed in seconds. For example, with a chart speed of 12 hours, the print interval is 12 seconds.
PRINT RANGE LIST - Chart Prompts - Chart Configuration - Page
The choice for the parameter ACTION ON NEW CHART that prints a list of the scale range, units, and recorder tag for each “Recorder” configured. If the Recorder is using two zones or does not use 100% of the printable chart span, the designation NL (for
PRINT SCALES - Chart Prompts - Chart Configuration - Page
The choice for the parameter ACTION ON NEW CHART that prints a set of scales for each Recorder configured.
PROCESS VARIABLES - System Prompts - Configuration - Page
Prompts section that configures up to four Process Variables, which can be used for alarming or to take advan- tage of the 4 PVS Display Format.
Appendix C | Edition 3 |
Rev G