Brady 3481, 6441, 2461 manual Communications, Serial Port A, Serial Port B, Parallel Port A

Models: 6441 2461 3481

1 140
Download 140 pages 59.06 Kb
Page 57
Image 57
4.1.6 Communications

4.1.6 Communications

SERIAL PORT A

Controls the communications settings for

 

 

 

Serial Port A.

 

BAUD RATE

Determines the serial communication rate.

 

 

 

 

 

 

38400

38400 bits per second

 

28800

28800 bits per second

 

19200

19200 bits per second

 

²9600

9600 bits per second

 

4800

4800 bits per second

 

2400

2400 bits per second

 

1200

1200 bits per second

 

 

PROTOCOL

Sets the data flow control (handshaking)

 

 

 

method.

 

 

²BOTH

Uses both handshaking methods.

 

 

SOFTWARE

XON/XOFF

 

 

HARDWARE

CTS/DTR

 

 

NONE

No flow control is used.

 

PARITY

Sets Word parity

 

 

 

 

 

 

²NONE

No parity

 

 

ODD

Odd parity

 

 

EVEN

Even parity

 

DATA BITS

Sets Word length

 

 

 

 

 

7

Seven bit Word length

 

²8

Eight bit Word length

 

STOP BITS

Sets the number of stop bits

 

 

 

 

 

²1

One stop bit

 

2

Two stop bits

SERIAL PORT B

Same as Serial Port A, for an optional connection. If not present, this displays ‘NOT INSTALLED’ when accessed.

 

 

Controls the communications settings for

PARALLEL PORT A

Parallel Port A.

 

 

 

 

PORT DIRECTION

Determines if messages are sent from the

 

 

 

printer to the host via the parallel port.

 

 

²UNI-DIRECTIONAL

One-way printer communication.

 

 

 

 

BI-DIRECTIONAL

Enables IEEE 1284 back-channel operation.