Advanced Entry Calibration (continued)

 

Step

Operator Action

 

Displayed Message

Comment

 

 

13

Using the

 

 

 

key,

 

 

Selection is

 

 

 

 

 

 

 

 

 

 

select the Gain Number

 

 

denoted with an

 

 

 

 

 

 

 

 

determined in Step 12.

 

 

‘*’.

 

 

 

 

 

 

 

 

 

 

 

 

 

Press the

 

 

 

key to

 

Or, for reflective media:

 

 

 

 

 

 

 

 

 

 

 

 

select the setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14 Œ Place the media in the

 

 

Where ‘yyy’ is

 

 

 

 

 

 

 

Media Sensor. Record

 

 

a numerical

 

 

 

 

 

 

 

 

the sensor reading and

 

 

value

 

 

 

 

 

 

 

 

 

 

 

 

 

label it

‘P’ (paper).

 

Or, for reflective media:

representing the

 

 

 

Place the backing, mark,

 

 

current sensor

 

 

 

 

 

reading.

 

 

 

or notch in the Media

 

 

 

 

 

 

 

 

 

 

 

Sensor. Record the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sensor reading and label

 

 

 

 

 

 

it ‘G’ or ‘M’ (Gap or

 

 

 

 

 

 

Mark).

 

 

 

 

 

 

 

 

ŽRemove all media. Record the sensor reading and label it ‘E’ (Empty).

15

Press the key. Then press the key.

The sensor readings must be manually entered into the printer now.

69

Page 79
Image 79
Brady 6441, 3481, 2461 manual Step Operator Action Displayed Message Comment