Brady 3481, 6441 Advanced Entry Calibration, Step, Operator Action, Displayed Message, Comment

Models: 6441 2461 3481

1 140
Download 140 pages 59.06 Kb
Page 75
Image 75
5.0.2Advanced Entry Calibration

5.0.2Advanced Entry Calibration

Advanced Entry Calibration is the alternate method for special-case media types. The procedure has two parts:

1)Using different sampling algorithms, displayed sensor readings have to be listed for each label and TOF value.

2)From this data, the best algorithm is chosen; then those values are manually entered for the ‘Paper’, ‘Gap’ (or ‘Mark’), and ‘Empty’ variables.

+Advanced Entry Calibration will override all previous calibration settings; this method should be used only when Standard Calibration has failed.

To perform an Advanced Entry Calibration:

Step

Operator Action

Displayed Message

Comment

1

(Media should be loaded

 

Wait until the

 

 

and the appropriate

 

printer initializes

 

 

 

Sensor Type selected.)

 

(about six

 

 

 

Turn ‘On’ the printer.

 

seconds).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Press the

 

 

 

 

 

 

 

 

 

 

 

 

 

key.

 

You are entering

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Menu Mode.

 

Raise the printhead

 

 

 

 

 

 

 

 

 

 

 

 

assembly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Press the

 

 

 

 

 

 

key to

 

See Section 4.1.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

enter the Media Settings

 

for menu layout.

 

 

 

menu.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Press the

 

 

 

 

 

 

key

 

Press the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and scroll to ‘Sensor

 

key to abort this

 

 

 

 

 

Calibration’.

 

 

 

 

 

 

 

 

procedure.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Press the

 

 

 

 

 

 

key.

 

You are entering

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the calibration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

submenu.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

Page 75
Image 75