Setting Logon Options

 

 

Field

Description

 

 

Application ID

The OMEGAMON II classic interface VTAM mode application

 

identifier.

 

 

DB2 subsystem

The DB2 subsystem ID that you want to monitor.

 

 

Logical rows

The number of logical rows (100–9999).

 

 

Migrate Profile from

Enter Yes if you want to migrate a classic interface user profile to a

OMEGAMON

CUA subsystem profile. Use this feature only to provide a set of

 

values to use as a starting point for customizing the CUA subsystem

 

profile.

 

When you migrate classic threshold values, they become CUA critical

 

values.

 

If a CUA exception is set to trip when it exceeds its threshold, then

 

the warning threshold is set to 80% of the critical threshold. If a CUA

 

exception is set to trip when it falls below its threshold, then the

 

warning threshold is set to 125% of the critical threshold.

 

For exceptions that are not associated with threshold values, the CUA

 

critical value is set to on, and the warning value is set to off. If the

 

classic STATE= value is ON, the CUA monitor value is YES. If the

 

value for STATE= is OFF, the monitor value is NO.

 

 

OMEGAMON Profile to

The suffix of the profile you want to migrate from the classic

Migrate

OMEGAMON II system.

 

 

User Data

Additional classic interface options, such as USER=cc.

 

Note: During normal operations, this field should be left blank.

 

 