[D] Fourth WRITE manager name or IP address

[X]Exit to previous menu

7.At this point you can select option [1] and configure the WRITE community string and change the default community string from “private” to “techwrite,” as we did in the following:

Catalyst 1900 − Network Management (SNMP) WRITE Configuration

—————————————————————— Settings ——————————————————

[1]First WRITE community string

[2]Second WRITE community string

[3]Third WRITE community string

[4]Fourth WRITE community string

[A] First

WRITE manager name or IP address

63.78.39.84

[B] Second

WRITE manager name or IP address

 

[C]

Third

WRITE

manager

name or IP address

 

[D]

Fourth WRITE

manager

name or IP address

 

[X]Exit to previous menu

Enter Selection: 1

This command configures the community string the switch will recognize on all SNMP read/w

Enter WRITE community string:

Current setting ===> private

New setting ===> techwrite

8.Again, once you have entered the new setting, your screen will automatically refresh. At this point, enter option [X] and return to the SNMP configuration menu.

9.At the Network Management (SNMP) Configuration Menu, select [T]. This will allow you to configure the trap message configuration settings:

Catalyst 1900 − Network Management (SNMP) Configuration

[R]READ configuration

[W]WRITE configuration

[T]TRAP configuration

[X]Exit to previous menu

Enter Selection: T

Catalyst 1900 −

Network Management (SNMP) TRAP Configuration

——————————— Settings ——————————————————

 

[1]

First TRAP community string

 

[A] First TRAP manager name or IP address

 

[2]

Second TRAP

community string

 

[B] Second TRAP

manager name or IP address

 

[3]

Third TRAP community string

 

[C] Third TRAP manager name or IP address

 

[4]

Fourth TRAP

community string

 

[D] Fourth TRAP

manager name or IP address

 

[U] Authentication trap generation

Enabled

[L] LinkUp/LinkDown trap generation

Enabled

[X]Exit to previous menu

Enter Selection:

302

Page 318
Image 318
Cisco Systems RJ-45-to-AUX manual 302