epld 3.1 30 72920 06/14/99 19:33:06
lcp atm 3.1 12−15 23747 06/14/99 11:16:06
lcp tr 3.1 12−15 28737 06/14/99 11:17:19
lcp c5ip 3.1 12−15 23723 06/14/99 11:26:40
lcp 64k 3.1 12−15 57100 06/14/99 11:28:15
atm/fddi 3.1 12−15 24502 06/14/99 11:47:07
lcp 360 3.1(212) 12−15 120648 06/14/99 01:32:33
mcp 3.1 12−15 26278 06/14/99 11:50:41
Catalyst5002>

Note There is no comparable command on the 1900EN series switches.

Testing the Supervisor Engine Hardware on a Set/Clear
Command−Based Switch

To test the Supervisor Engine module on a Set/Clear command−based switch, use the show test command.

Let’s take a look at the command, its optional syntax, and an example of its output:

show test [module number]
Catalyst5002> (enable) show test
Environmental Status (. = Pass, F = Fail, U = Unknown)
PS (3.3V): . PS (12V): . PS (24V): . PS1: . PS2: .
Temperature: . Fan: . Clock(A/B): A Chassis−Ser− EEPROM: .
Module 1 : 2−port 100BaseFX MM Supervisor
Network Management Processor (NMP) Status:
(. = Pass, F = Fail, U = Unknown)
ROM: . Flash−EEPROM: . Ser−EEPROM: . NVRAM: . MCP Comm: .
EARL Status :
NewLearnTest: .
IndexLearnTest: .
DontForwardTest: .
MonitorTest .
DontLearn: .
FlushPacket: .
ConditionalLearn: .
EarlLearnDiscard: .
EarlTrapTest: .
LCP Diag Status for Module 1 (. = Pass, F = Fail, N = N/A)
CPU : . Sprom : . Bootcsum : . Archsum : N
RAM : . LTL : . CBL : . DPRAM : . SAMBA : .
Saints : . Pkt Bufs : . Repeater : N FLASH : N
MII Status:
Ports 1 2
——————————
N N
SAINT/SAGE Status :
Ports 1 2 3
——————————————
. . .
Packet Buffer Status :
Ports 1 2 3
——————————————
. . .
Loopback Status [Reported by Module 1] :
Ports 1 2 3

322