control distribute: vcd 1452, 3 members, 196 packets

proxy/ (ST: Init, Conn, Waiting, Adding, Joined, Operational, Reject, Term)

lecid ST vcd pkts Hardware Addr ATM Address

1 O 1451 6 0060.705a.8f02 47.0091810000000060707B8A01.0060705A8B12.01

2 O 1455 10 00e0.d7b1.ba12 47.0091810000000060707B8A01.112233461176.02

3P O 1466 59 0090.a2fb.b430 47.0091810000000060707B8A01.009086FB1021.01

LE BUS ATM2/0.2 ELAN name: elan1 Admin: up State: operational

type: ethernet Max Frame Size: 1516

ATM address: 47.009181000000006007B8A01.1B2133CC51BA.02

data forward: vcd 1454, 3 members, 244 packets, 5 unicasts

lecid vcd

pkts ATM Address

1

1453

32

47.0091810000000060707B8A01.0060705A8B12.01

2

1458

28

47.0091810000000060707B8A01.112233461176.02

3

1467

58

47.0091810000000060707B8A01.0060705A8B12.01

LE Client ATM2/0.2 ELAN name: elan1 Admin: up State: operational

Client ID: 2

LEC up for 22 minutes 53 seconds

Join Attempt:

605

 

 

HW Address: 00e0.f9b1.b410

Type: ethernet Max Frame Size: 1516

ATM Address: 47.0091810000000060707B8A01.112233461176.02

VCD rxFrames

txFrames Type

ATM Address

 

0

0

0 configure

 

 

00.000000000000000000000000.000000000000.00

 

1456

1

10 direct

 

 

47.0091810000000060707B8A01.112233461176.02

 

1457

196

0 distribute

 

 

47.0091810000000060707B8A01.112233461176.02

 

1459

0

28 send

 

 

47.0091810000000060707B8A01.112233461176.02

 

1460

245

0 forward

 

 

47.0091810000000060707B8A01.112233461176.02

 

 

 

 

 

Related solution:

 

 

Found on page:

Verifying a LEC Configuration on an ELAN

272

Viewing the Installed Modules

Just as you can on a Catalyst switch, you can use the show module command to look at the installed modules on the LightStream switch. Remember, the LS1010 can use the same modules as the 5500 series switch. Here’s an example of the command’s results:

CoriolisLS1010> show module

 

 

 

Mod Module−Name

Ports Module−Type

Model

Serial−Num

Status

—— ——————————————

————

————————————————————

———————— ——————————

——————

2

2

100BaseTX Supervisor

WS−X5509

002261212

ok

3

24

3 Segment 100BaseTX E

ws−x5223

000000021

ok

4

1

MM OC−3 ATM

WS−X5155

003125674

ok

5

2

MM MIC FDDI

WS−X5101

002774545

ok

6

 

Route Switch Ext Port

 

 

 

7

1

Route Switch

WS−X5302

002274941

ok

Mod

MAC−Address(es)

Hw

Fw

Sw

———

————————————————————————————————————————

——————

—————— —————————

2

00−e0−a3−a5−00−00 thru 00−e0−a3−a5−03−ff

1.2

2.2(1)

3.1(1)

3

00−60−83−42−e4−4b thru 00−60−83−42−e4−4d

0.1

2.2(4)

3.1(1)

4

00−40−0b−43−02−64

1.0

1.3

2.2

5

00−60−3e−cd−42−95

1.0

1.1

2.1(2)

7

00−40−0b−91−42−16 thru 00−40−0b−91−42−17

1.0

20.2

11.2

Mod

Sub−Type Sub−Model Sub−Serial Sub−Hw

 

 

 

192

Page 208
Image 208
Cisco Systems RJ-45-to-AUX manual Viewing the Installed Modules, 192