3.5.3 Serial Port Settings
This applies only if you use RS232 commands to control the Bay Cat X.
If you wish to control Bay Cat Xs remotely with RS232 commands from a computer, read this section. Otherwise, skip it.
Bay Cat Xs can be linked together for RS232 using
RS232 is also used to upgrade the firmware of the unit.
Adapter from computer to RJ45
At the computer end, you will need an adapter to go from the computer’s
Wiring the adapter
To go from
Yellow wire | pin 3 |
Black wire | pin 2 |
Green wire | pin 5 |
|
|
RJ45 | |
|
|
|
|
6 | 3 |
55
32
Connect all the Bay Cat Xs together through their RS232 ports: from the computer to the first Bay Cat X RS232 IN; from the first Bay Cat X RS232 OUT to the next Bay Cat X RS232 IN, etc. It doesn’t matter what order you string them together. Most RS232 signals easily travel up to 150 ft. (50 m) between Bay Cat Xs.
Setting Unit IDs
Each Bay Cat X in the RS232 series needs a unique ID
so it can be individually addressed. To set unit IDs, go to Main Menu > Advanced Options > Serial Port Set- tings.
w
Main Menu
Picture
Size & Position
Aspect Ratio & Wall
Memory
Diagnostics
Advanced Options | “ | ||
|
| ||
Program Information |
|
| |
|
|
|
|
Advanced Options |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Color Balance |
|
| |
Miscellaneous Options |
|
| |
Backlight Settings |
|
| |
Serial Port Settings |
|
| |
Auto Setup Options |
|
| |
Menu Options |
|
| |
Message in Picture |
|
| |
Capture Custom Logo |
|
| |
|
|
|
|
5 | 4 | 3 | 2 | 1 |
9 8 7 6
1 | 8 |
female
Serial Port Settings |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Group ID | 1 |
| |
Unit ID | 1 |
| |
ASCII Response Type | Symbolic | ||
ASCII Response Terminator | CR | ||
Baud Rate | 19200 |
|
RJ45 looking into the socket.
60