The ID is in two parts, Group ID and Unit ID. Each of these has a range of 0–9, A–Z. This range results in 1296 possible addresses.

You can group the Bay Cat Xs by using the same letter or number of the Group ID, such as 8. In this way you can address the group as 8*, and all the Bay Cat Xs in the string that have Group ID 8 and any Unit ID will execute the com- mand. See the RS232 programming guide for Bay Cat X (part number 070-0108-02 or later) on www.ClarityVi- sual.com/login/.

1.Click the lower, blue button.

2.Use the name “tech” and password “help”.

Response type and terminator

The ASCII Response Type determines what type of data will be returned to the computer. For human readable text in a serial program choose Symbolic. For computer- read data you can use Numeric or Data Only.

The ASCII Response Terminator will be determined by what your serial program wants to see at the end of every transmission from the Bay Cat X.

Baud Rate must be the same as that used by the con- trolling computer. The baud rate is not automatically set, as it is with modem communications. It must be manually set here and at the computer to match each other.

For firmware upgrades, you don’t need to adjust the baud rate.

Diagnostics for RS232

To view RS232 port status, go to Main Menu > Diag-

nostics > RS232 Port Status.

Diagnostics

Unit Status

RS232 Port Status

Test Patterns

Setup Summary

Hours

Serial Port Status RS232

Press <enter> to clear

Commands Received

34

Replies Sent

34

Last Packet Type

Operation

Last Packet Address

Not Addressed

Bytes Received

921

Bytes Sent

773

UART Framing Errors

4

UART Overflow Errors

0

Group 0 Unit: 0

19200 Baud

 

Most Recent

... 103, 105, 116, 97, 108. 46, 82, 71, 66, 13

--select.source=Digital.RGB.

The Serial Port Status RS232 menu lists items that

concern RS232. For more information, see “Serial Port Sta- tus Settings” on page 91.