Control Method

V/F Control

 

CONTROL

Frequency Setting Resolution

Digital Reference: 0.01 Hz (Below 100 Hz), 0.1 Hz (Over 100 Hz)

Analog Reference: 0.03 Hz / 50 Hz

 

 

 

 

 

Frequency Accuracy

Digital: 0.01 % of Max. Output Frequency, Analog: 0.1 % of Max. Output Frequency

V/F Ratio

 

 

Linear, Square Patter, User V/F

 

 

Overload Capacity

150 % of Rated Current for 1 Min. (Characteristic is inversely Proportional to Time)

 

Torque Boost

Manual Torque Boost (0 ~ 15 %), Auto Torque Boost

 

 

Operation Method

Key / Terminal / Communication Operation

 

 

Frequency Setting

Analog: 0 ~ 10V / 4 ~ 20 mA

Digital: Keypad

 

Signal

Start Signal

Forward, Reverse

 

 

Multi-Step Speed

Up to 8 Speeds Can Be Set (Use Multi-Function Terminal)

 

Multi Step Accel/Decel Time

0 ~ 9,999 sec, Up to 4 Types Can Be Set and Selected for Each Setting (Use Multi-

 

 

 

 

Function Terminal), Accel/Decel Pattern: Linear Pattern, U Pattern, S Pattern

 

 

 

 

 

 

 

 

Emergency Stop

Interrupts the Output of Inverter

 

 

 

Jog

 

 

Jog Operation

 

 

 

Fault Reset

Reset Faults When Protective Function is Active

OPERATION

SignalInput

Operating Status

Frequency Level Detection, Overload Alarm, Stalling, Over Voltage, Under Voltage,

Inverter Overheating, Running, Stop, Constant Speed, Speed Searching

 

 

 

 

 

Fault Output

Contact Output (A, C, B) – AC250V 1A, DC30V 1A

 

Output

 

Indicator

Choose One From Output Frequency, Output Current, Output Voltage, DC Voltage

 

 

 

 

 

 

(Output Voltage: 0 ~ 10V)

 

 

Operation Function

DC Braking, Frequency Limit, Frequency Jump, Second Function, Slip

 

Compensation, Reverse Rotation Prevention, Auto Restart, PID Control

 

 

 

 

 

 

 

Inverter Trip

Over Voltage, Under Voltage, Over Current, Inverter Overheating, Motor Over

Protection

heating, Input/Output Phase Loss, Overload Protection, Communication Error, Loss

 

 

 

 

 

of Speed Command, Hardware Fault

Inverter Alarm

Stall Prevention, Overload Alarm

 

Momentary Power Loss

Less than 15 msec: Continuous Operation,

 

 

More than 15 msec: Auto Restart (Programmable)

 

 

 

 

 

 

Display

Keypad

 

Operation Information

Output Frequency, Output Current, Output Voltage, Frequency Value Setting,

 

Operating Speed, DC Voltage

 

 

 

 

 

 

 

 

Trip Information

Indicates Fault when Protection Function Activated, Memorizes Up to 5 Faults

 

 

 

 

 

Ambient

Temperature

-10 °C ~ 40 °C (14 °F ~ 104 °F), CE Certification: 41 °F ~ 104 °F (5 °C ~ 40 °C)

Environment

Storage Temperature

-20 °C ~ 65 °C (-4 °F ~ 149 °F)

Ambient Humidity

Less Than 90 % RH Max. (Non-Condensing),

CE Certification: 5 ~85% (Non-Condensing)

 

 

 

 

 

Altitude / Vibration

Below 1,000 m · Below 5.9m/sec² (=0.6g)

Application Site

No Corrosive Gas, Combustible Gas, Oil Mist, or Dust

 

 

Atmospheric Pressure

70 ~ 106kPa

 

Cooling Method

Forced Air Cooling4

 

 

 

 

 

 

 

 

 

4‘Self-cooling’ for model SV004ACtionMaster -4, SV008ACtionMaster -4.