Cleveland Range inverter Parameter Description I/O, I/O-42 FDT Frequency Detection Level, Current

Models: inverter

1 119
Download 119 pages 48.5 Kb
Page 75
Image 75
[Frequency]

Chapter 4 - Parameter Description [I/O]

average ranges from 0V to 10V. I/O-41 is used to adjust the FM value.

[Frequency]

FM terminal outputs inverter output frequency. The output value is determined by,

FM Output Voltage = (Output freq. / Max. freq.) × 10V × IO- 41 / 100

[Current]

FM terminal outputs inverter output current. The output value is determined by,

FM Output Voltage = (Output current / Rated current) × 10V × IO-41 / 150

[Voltage]

FM terminal outputs inverter output voltage. The output value is determined by,

FM Output Voltage = (Output voltage / Max. output voltage) × 10V × IO-41 / 100

[DC link vtg]

FM terminal outputs the DC link voltage of inverter. The output value is determined by,

FM Output Voltage = (DC link voltage / Max. DC link voltage) × 10V × IO-41 / 100

I/O-42: FDT (Frequency Detection) Level

I/O-43: FDT Bandwidth

These functions are used in I/O-44 [Multi-function Output]. See [FDT-#] in I/O-44.

Related Functions: I/O-44 [Multi-function Output]

I/O-44: Multi-function Output define (MO-MG)

The open collector output works (Close) when the defined condition has occurred.

Setting Range

Description

Select

Display

 

FDT-1

0

Output frequency arrival detection

FDT-2

1

Specific frequency level detection

FDT-3

2

Frequency detection with pulse

FDT-4

3

Frequency detection with contact

closure

 

 

FDT-5

4

Frequency detection with contact

closure (inverted FDT-4)

 

 

OL

5

Overload detection

IOL

6

Inverter overload detection

Stall

7

Stall prevention mode detection

OV

8

Over voltage detection

LV

9

Low voltage detection

OH

10

Overheat detection

Lost Command

11

Lost command detection

Run

12

Inverter running detection

Stop

13

Inverter stop detection

Steady

14

Steady speed detection

-Reserved-

15 ~16

Reserved for future use

Ssearch

17

Speed search mode detection

-Reserved-

18 ~19

Reserved for future use

Ready

20

Inverter is ready status to run

69