P Gain

Chapter 3 - Parameter List

 

 

 

Keypad

 

 

Factory

Adj.

 

Code

Description

Setting Range

Units

During

Page

Display

Default

 

 

 

 

 

Run

 

 

 

 

 

 

 

 

 

FU2-24

P Gain

H 24

0 to 9999

1

100

Yes

53

 

During Speed Search

 

 

 

 

 

 

FU2-25

I Gain

H 25

0 to 9999

1

5000

Yes

53

 

During speed search

 

 

 

 

 

 

FU2-26

Number of Auto Restart Attempt

H 26

0 to 10

1

0

Yes

54

FU2-27

Delay Time before Auto Restart

H 27

0 to 60 [sec]

0.1

1.0 [sec]

Yes

 

 

 

 

 

0.4 (0.37kW)

 

 

 

 

 

 

 

 

0.8 (0.75kW)

 

 

 

 

FU2-30

Rated Motor Selection

H 30

1.5 (1.5kW)

-

13

No

54

2.2 (2.2kW)

 

 

 

 

 

 

 

 

 

 

 

 

3.7 (3.7kW)

 

 

 

 

 

 

 

 

4.0 (4.0kW)

 

 

 

 

FU2-31

Number of Motor Pole

H 31

2 to 12

1

4

No

 

FU2-3214

Rated Motor Slip

H 32

0 to 10 [Hz]

0.01

 

No

 

FU2-33

Rated Motor Current in RMS

H 33

0.1 to 99.9 [A]

1

14

No

54

FU2-3415

No Load Motor Current in RMS

H 34

0.1 to 99.9 [A]

1

No

 

 

FU2-36

Motor Efficiency

H 36

50 to 100 [%]

1

 

No

 

FU2-37

Load Inertia

H 37

0 to 2

1

0

No

 

FU2-39

Carrier Frequency

H 39

1 to 10 [kHz]

1

3 [kHz]

Yes

55

FU2-40

Control Mode Selection

H 40

0 (V/F)

-

0 (V/F)

No

56

1 (Slip Compen)

 

 

 

 

2 (PID)

 

 

 

 

FU2-5016

PID Feedback Signal Selection

H 50

0 (I)

-

I

No

 

1 (V1)

0

 

 

 

 

 

 

 

 

FU2-51

P Gain for PID Control

H 51

0 to 9999

1

3000

Yes

56

FU2-52

I Gain for PID Control

H 52

0 to 9999

1

300

Yes

 

FU2-53

D Gain for PID Control

H 53

0 to 9999

1

0

Yes

 

FU2-54

Limit Frequency for PID Control

H 54

0 to FU1-20

0.01

50 / 60 [Hz]

Yes

 

FU2-70

Reference Frequency for Accel and

H 70

0 (Max Freq)

-

Max frq

No

57

 

Decel

 

1 (Delta Freq)

 

0

 

 

FU2-71

Accel/Decel Time Scale

H 71

0 (0.01 sec)

-

1 (0.1 sec)

Yes

58

1 (0.1 sec)

 

 

 

 

2 (1 sec)

 

 

 

 

FU2-72

Power On Display

H 72

0 (Cmd. Freq)

1

0

Yes

58

 

 

 

 

1 (Acc. Time)

 

(Cmd. Freq)

 

 

 

 

 

 

2 (Dec. Time)

 

 

 

 

 

 

 

 

 

 

 

 

 

13The rated motor is automatically set according to the inverter model number. If a different motor is used, set the correct motor parameters.

14This value is automatically entered according to the rated motor set in FU2-30. If different, set the correct motor parameters.

15Code FU2-32 and FU2-34 appear only when FU2-40 is set to ‘Slip comp’.

16Code FU2-50 through FU2-54 appears only when FU2-40 is set to ‘PID’.

28