1.6 Basic Wiring

Chapter 1 - Installation

1.6 Basic Wiring

DB Resistor2

1Φ, 230V

MCCB

B1

B2

or

R

3 Φ,

 

 

230/460V

S

 

 

50/60Hz

T

 

 

 

G

 

 

Forward Run/Stop

FX

 

 

Reverse Run/Stop

 

 

RX

 

 

Inverter Disable

 

 

BX

 

 

Fault Reset

 

 

RST

 

 

Jog

 

 

JOG

 

 

Multi-function Input 1

 

 

P1

 

 

Multi-function Input 2

Factory Setting:

 

P2

 

Multi-function Input 3

‘Speed-L’

 

P3

‘Speed-M’

 

 

‘Speed-H’

30A

Common Terminal

 

CM

 

30C

 

 

 

 

 

30B

Potentiometer

Shield

 

 

(1 kohm, 1/2W)

 

Power supply for

 

 

VR speed signal:

 

 

 

+ 12V, 10mA

 

 

V1

Speed signal input:

 

 

 

0 ~ 10V

 

I

Speed signal input:

 

4 ~20mA (250ohm)

CM Common for

Speed signal Input1

VR, V1, I

 

UManual background

VManual background

W Manual background

FM Manual background

CM

MO

MG

S+ Manual background

S- Manual background

MOTOR

+

FM

 

Output Frequency Meter

 

 

 

(0~10V Analog)

 

 

 

Fault output relay

Less than AC250V, 1A

Less than DC30V, 1A

Less than DC24V, 50mA

Factory setting: ‘Run’

RS485 & MODBUS-RTU

Communication port

Note)

display main circuit terminals,

display control circuit terminals.

1.Analog speed command can be set by Voltage, Current and both of them.