Cleveland Range inverter manual Function Group 1 FU1, Parameter List

Models: inverter

1 119
Download 119 pages 48.5 Kb
Page 31
Image 31
Chapter 3 - Parameter List

Chapter 3 - Parameter List

3.2 Function Group 1 [FU1]

 

Code

Description

 

Keypad

Setting Range

Units

 

Factory

 

Adj.

Page

 

 

 

 

During

 

 

Display

 

Default

 

 

 

 

 

 

 

 

 

 

Run

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FU1-00

Jump to Desired Code #

 

F 0

1 to 99

1

3

 

Yes

39

 

FU1-03

Run Prevention

 

F 3

0 (None)

-

 

0 (None)

 

No

39

 

 

1 (Forward Prev)

 

 

 

 

 

 

 

2 (Reverse Prev)

 

 

 

 

 

 

 

 

 

 

 

0 (Linear)

 

 

 

 

 

 

 

FU1-05

Acceleration Pattern

 

F 5

1 (S-Curve)

-

 

0 (Linear)

 

No

39

 

 

2 (U-Curve)

 

 

 

 

 

 

 

3 (Minimum)

 

 

 

 

 

 

 

 

 

 

 

4 (Optimum)

 

 

 

 

 

 

 

 

 

 

 

0 (Linear)

 

 

 

 

 

 

 

FU1-06

Deceleration Pattern

 

F 6

1 (S-Curve)

-

 

0 (Linear)

 

No

39

 

 

2 (U-Curve)

 

 

 

 

 

 

 

3 (Minimum)

 

 

 

 

 

 

 

 

 

 

 

4 (Optimum)

 

 

 

 

 

 

 

FU1-07

Stop Mode

 

F 7

0 (Decel)

-

 

0 (Decel)

 

No

40

 

 

1 (DC-Brake)

 

 

 

 

 

 

 

2 (Free-Run)

 

 

 

 

 

 

 

FU1-087

DC Injection Braking Frequency

 

F 8

(FU1-22) to 50/60 [Hz]

0.01

 

5.00 [Hz]

 

No

 

 

FU1-09

DC Injection Braking On-delay Time

 

F 9

0 to 60 [sec]

0.01

 

0.10 [sec]

 

No

41

 

FU1-10

DC Injection Braking Voltage

 

F 10

0 to 200 [%]

1

50 [%]

 

No

 

 

 

 

 

FU1-11

DC Injection Braking Time

 

F 11

0 to 60 [sec]

0.1

 

1.0 [sec]

 

No

 

 

FU1-12

Starting DC Injection Braking

 

F 12

0 to 200 [%]

1

50 [%]

 

No

41

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

FU1-13

Starting DC Injection Braking Time

 

F 13

0.0 to 60.0 [sec]

0.1

 

0.0 [sec]

 

No

 

 

FU1-20

Maximum Frequency

 

F 20

40.00 to 400.00 [Hz]

0.01

 

50 / 60 [Hz]

 

No

42

 

FU1-21

Base Frequency

 

F 21

30.00 to (FU1-20)

0.01

 

50 / 60 [Hz]

 

No

 

FU1-22

Starting Frequency

 

F 22

0.10

to 10.00 [Hz]

0.01

 

0.10 [Hz]

 

No

 

 

FU1-23

Frequency Limit Selection

 

F 23

0 (No)

-

 

0 (No)

 

No

 

 

 

1 (Yes)

 

 

42

 

 

 

 

 

 

 

 

 

 

 

FU1-248

Low Limit Frequency

 

F 24

0.00

to (FU1-25)

0.01

 

0.00 [Hz]

 

No

 

 

 

 

 

 

FU1-25

High Limit Frequency

 

F 25

(FU1-24) to (FU1-20)

0.01

 

50 / 60 [Hz]

 

No

 

 

FU1-26

Manual/Auto Torque Boost

 

F 26

0 (Manual)

-

 

0 (Manual)

 

No

 

 

 

1 (Auto)

 

 

 

 

 

Selection

 

 

 

 

 

 

 

43

 

FU1-27

Torque Boost in Forward Direction

 

F 27

0.0 to 15.0 [%]

0.1

2.0 [%]

 

No

 

 

 

 

 

FU1-28

Torque Boost in Reverse Direction

 

F 28

0.1

2.0 [%]

 

No

 

 

 

 

 

 

 

7Code FU1-08 through FU1-11 appears only when FU1-07 is set to ‘DC-brake’.

8Code FU1-24 through FU1-25 appears only when FU1-23 is set to ‘Yes’.

25

Page 31
Image 31
Cleveland Range inverter manual Function Group 1 FU1, Parameter List