Chapter 3 - Parameter List

3.2 Function Group 1 [FU1]

 

Code

Description

 

Keypad

Setting Range

Units

 

Factory

 

Adj.

Page

 

 

 

 

During

 

 

Display

 

Default

 

 

 

 

 

 

 

 

 

 

Run

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FU1-00

Jump to Desired Code #

 

F 0

1 to 99

1

3

 

Yes

39

 

FU1-03

Run Prevention

 

F 3

0 (None)

-

 

0 (None)

 

No

39

 

 

1 (Forward Prev)

 

 

 

 

 

 

 

2 (Reverse Prev)

 

 

 

 

 

 

 

 

 

 

 

0 (Linear)

 

 

 

 

 

 

 

FU1-05

Acceleration Pattern

 

F 5

1 (S-Curve)

-

 

0 (Linear)

 

No

39

 

 

2 (U-Curve)

 

 

 

 

 

 

 

3 (Minimum)

 

 

 

 

 

 

 

 

 

 

 

4 (Optimum)

 

 

 

 

 

 

 

 

 

 

 

0 (Linear)

 

 

 

 

 

 

 

FU1-06

Deceleration Pattern

 

F 6

1 (S-Curve)

-

 

0 (Linear)

 

No

39

 

 

2 (U-Curve)

 

 

 

 

 

 

 

3 (Minimum)

 

 

 

 

 

 

 

 

 

 

 

4 (Optimum)

 

 

 

 

 

 

 

FU1-07

Stop Mode

 

F 7

0 (Decel)

-

 

0 (Decel)

 

No

40

 

 

1 (DC-Brake)

 

 

 

 

 

 

 

2 (Free-Run)

 

 

 

 

 

 

 

FU1-087

DC Injection Braking Frequency

 

F 8

(FU1-22) to 50/60 [Hz]

0.01

 

5.00 [Hz]

 

No

 

 

FU1-09

DC Injection Braking On-delay Time

 

F 9

0 to 60 [sec]

0.01

 

0.10 [sec]

 

No

41

 

FU1-10

DC Injection Braking Voltage

 

F 10

0 to 200 [%]

1

50 [%]

 

No

 

 

 

 

 

FU1-11

DC Injection Braking Time

 

F 11

0 to 60 [sec]

0.1

 

1.0 [sec]

 

No

 

 

FU1-12

Starting DC Injection Braking

 

F 12

0 to 200 [%]

1

50 [%]

 

No

41

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

FU1-13

Starting DC Injection Braking Time

 

F 13

0.0 to 60.0 [sec]

0.1

 

0.0 [sec]

 

No

 

 

FU1-20

Maximum Frequency

 

F 20

40.00 to 400.00 [Hz]

0.01

 

50 / 60 [Hz]

 

No

42

 

FU1-21

Base Frequency

 

F 21

30.00 to (FU1-20)

0.01

 

50 / 60 [Hz]

 

No

 

FU1-22

Starting Frequency

 

F 22

0.10

to 10.00 [Hz]

0.01

 

0.10 [Hz]

 

No

 

 

FU1-23

Frequency Limit Selection

 

F 23

0 (No)

-

 

0 (No)

 

No

 

 

 

1 (Yes)

 

 

42

 

 

 

 

 

 

 

 

 

 

 

FU1-248

Low Limit Frequency

 

F 24

0.00

to (FU1-25)

0.01

 

0.00 [Hz]

 

No

 

 

 

 

 

 

FU1-25

High Limit Frequency

 

F 25

(FU1-24) to (FU1-20)

0.01

 

50 / 60 [Hz]

 

No

 

 

FU1-26

Manual/Auto Torque Boost

 

F 26

0 (Manual)

-

 

0 (Manual)

 

No

 

 

 

1 (Auto)

 

 

 

 

 

Selection

 

 

 

 

 

 

 

43

 

FU1-27

Torque Boost in Forward Direction

 

F 27

0.0 to 15.0 [%]

0.1

2.0 [%]

 

No

 

 

 

 

 

FU1-28

Torque Boost in Reverse Direction

 

F 28

0.1

2.0 [%]

 

No

 

 

 

 

 

 

 

7Code FU1-08 through FU1-11 appears only when FU1-07 is set to ‘DC-brake’.

8Code FU1-24 through FU1-25 appears only when FU1-23 is set to ‘Yes’.

25

Page 31
Image 31
Cleveland Range inverter manual Function Group 1 FU1, Parameter List

inverter specifications

The Cleveland Range inverter is a state-of-the-art piece of kitchen equipment designed to elevate cooking efficiency and precision in commercial kitchens. This versatile appliance is particularly well-suited for establishments such as restaurants, cafeterias, and catering operations, where high-performance and reliability are critical to success.

One of the standout features of the Cleveland Range inverter is its innovative inverter technology. Unlike traditional cooking equipment that utilizes standard heating elements, the inverter system allows for continuous, variable power control. This means that cooks can seamlessly adjust the cooking temperature, offering unparalleled control over the cooking process. The result is more consistent cooking outcomes and a significant reduction in food preparation time, ensuring that dishes are cooked just right every time.

Another characteristic that sets the Cleveland Range inverter apart is its energy efficiency. The inverter technology not only enhances cooking precision but also utilizes energy more effectively, leading to reduced power consumption. This is particularly beneficial for commercial kitchens where energy costs can quickly add up. By minimizing energy waste, the Cleveland Range inverter contributes to a more sustainable kitchen operation.

Safety is also a prime focus of the Cleveland Range inverter. With built-in safety features such as automatic shut-off functions, the appliance ensures that accidental overheating or overcooking is avoided, safeguarding both the kitchen staff and the food being prepared. Additionally, the design of the inverter is user-friendly, making it accessible for cooks at all experience levels.

Durability and ease of maintenance are further characteristics of the Cleveland Range inverter. Built with high-quality materials and a robust construction, it is designed to withstand the rigors of a busy kitchen environment. The straightforward design allows for easy cleaning and maintenance, ensuring that the inverter remains in top working condition over its lifespan.

In conclusion, the Cleveland Range inverter stands out in the commercial kitchen landscape due to its innovative inverter technology, energy efficiency, safety features, and durability. It is an excellent investment for any culinary operation looking to enhance its cooking capabilities while maintaining high standards of food quality and safety. This appliance not only meets the demands of modern kitchens but also sets a benchmark for others in the industry.