Chapter 3 - Parameter List

 

 

Keypad

 

 

Factory

Adj.

 

Code

Description

Setting Range

Units

During

Page

Display

Default

 

 

 

 

Run

 

 

 

 

 

 

 

 

 

 

 

0 (No)

 

 

 

 

 

 

 

1 (All Groups)

 

 

 

 

FU2-93

Initialize Parameters

H 93

2 (DRV)

-

0 (No)

No

60

3 (FU1)

 

 

 

 

 

 

 

 

 

 

4 (FU2)

 

 

 

 

 

 

 

5 (I/O)

 

 

 

 

FU2-94

Parameter Write Protection

H 94

0 to 25518

1

0

Yes

60

FU2-99

Return Code

rt

 

-

-

Yes

60

3.4 Input/Output Group [I/O]

 

 

Keypad

 

 

Factory

Adj.

 

Code

Description

Setting Range

Units

During

Page

Display

Default

 

 

 

 

Run

 

 

 

 

 

 

 

 

I/O-00

Jump to Desired Code #

I 0

1 to 99

1

1

Yes

62

I/O-01

Filtering Time Constant for V1

I 1

0 to 9999 [ms]

1

100 [ms]

Yes

 

Signal Input

 

 

 

 

 

 

 

 

I/O-02

V1 Input Minimum Voltage

I 2

0 to I/O-04

0.01

0.00 [V]

Yes

 

I/O-03

Frequency corresponding to V1

I 3

0 to FU1-20

0.01

0.00 [Hz]

Yes

62

Input Minimum Voltage

 

 

 

 

 

 

 

I/O-04

V1 Input Maximum Voltage

I 4

(I/O-02) to 12.00 [V]

0.01

10.00 [V]

Yes

 

I/O-05

Frequency corresponding to V1

I 5

0.00 to (FU1-20)

0.01

50 / 60 [Hz]

Yes

 

Input Maximum Voltage

 

 

 

 

 

 

 

 

I/O-06

Filtering Time Constant for I Signal

I 6

0 to 9,999 [ms]

1

100 [ms]

Yes

 

Input

 

 

 

 

 

 

 

 

I/O-07

I Input Minimum Current

I 7

0.00 to (I/O-09)

0.01

4.00 [mA]

Yes

 

I/O-08

Frequency corresponding to I Input

I 8

0.00 to (FU1-20)

0.01

0.00 [Hz]

Yes

62

Minimum Current

 

 

 

 

 

 

 

I/O-09

I Input Maximum Current

I 9

(I/O-07) to 24.00[mA]

0.01

20.00 [mA]

Yes

 

I/O-10

Frequency corresponding to I Input

I 10

0.00 to (FU1-20)

0.01

50 /60 [Hz]

Yes

 

Maximum Current

 

 

 

 

 

 

 

 

I/O-11

Criteria for Analog Input Signal Loss

I 11

0 (None)

-

0 (No)

Yes

63

1 (Half of x1)

 

 

 

2 (Below x1)

 

 

 

 

I/O-12

Multi-function Input Terminal ‘P1’

I 12

0 (Speed-L)

-

0 (Speed-L)

No

64

 

Define

 

1 (Speed-M)

 

 

 

 

 

 

 

2 (Speed-H)

 

 

 

 

18This function is used to lock the parameters from being changed. Keypad displays “U 0” when the parameters are unlocked and “L 0” when locked. The lock and unlock code is ‘12’.

30

Page 36
Image 36
Cleveland Range inverter manual Input/Output Group I/O, 50 /60 Hz

inverter specifications

The Cleveland Range inverter is a state-of-the-art piece of kitchen equipment designed to elevate cooking efficiency and precision in commercial kitchens. This versatile appliance is particularly well-suited for establishments such as restaurants, cafeterias, and catering operations, where high-performance and reliability are critical to success.

One of the standout features of the Cleveland Range inverter is its innovative inverter technology. Unlike traditional cooking equipment that utilizes standard heating elements, the inverter system allows for continuous, variable power control. This means that cooks can seamlessly adjust the cooking temperature, offering unparalleled control over the cooking process. The result is more consistent cooking outcomes and a significant reduction in food preparation time, ensuring that dishes are cooked just right every time.

Another characteristic that sets the Cleveland Range inverter apart is its energy efficiency. The inverter technology not only enhances cooking precision but also utilizes energy more effectively, leading to reduced power consumption. This is particularly beneficial for commercial kitchens where energy costs can quickly add up. By minimizing energy waste, the Cleveland Range inverter contributes to a more sustainable kitchen operation.

Safety is also a prime focus of the Cleveland Range inverter. With built-in safety features such as automatic shut-off functions, the appliance ensures that accidental overheating or overcooking is avoided, safeguarding both the kitchen staff and the food being prepared. Additionally, the design of the inverter is user-friendly, making it accessible for cooks at all experience levels.

Durability and ease of maintenance are further characteristics of the Cleveland Range inverter. Built with high-quality materials and a robust construction, it is designed to withstand the rigors of a busy kitchen environment. The straightforward design allows for easy cleaning and maintenance, ensuring that the inverter remains in top working condition over its lifespan.

In conclusion, the Cleveland Range inverter stands out in the commercial kitchen landscape due to its innovative inverter technology, energy efficiency, safety features, and durability. It is an excellent investment for any culinary operation looking to enhance its cooking capabilities while maintaining high standards of food quality and safety. This appliance not only meets the demands of modern kitchens but also sets a benchmark for others in the industry.