APPENDIX A - FUNCTIONS BASED ON THE USE

APPENDIX A - FUNCTIONS BASED ON THE USE

Set the function properly according to the load and operating conditions. The application and the related functions are listed at the following table.

 

Use

 

 

Related Parameter Code

 

 

Accel/Decel time, pattern adjustment

 

 

DRV-01 [Acceleration Time], DRV-02 [Deceleration Time],

 

 

 

 

FU1-05 [Acceleration Pattern], FU1-06 [Deceleration Pattern]

 

 

 

 

 

 

 

Reverse rotation prevention

 

 

FU1-03 [Forward, Reverse Prevention]

 

 

Minimum time Accel/Decel

 

 

FU1-05 [Acceleration Pattern], FU1-06 [Deceleration Pattern]

 

 

Accel/Decel at continuous rating range

 

 

FU1-05 [Acceleration Pattern], FU1-06 [Deceleration Pattern]

 

 

Braking operation adjustment

 

 

FU1-07 [Stop Method], FU1-08~11 [DC Braking],

 

 

 

 

FU1-12~13 [DC braking at Start]

 

 

 

 

 

 

 

 

 

 

FU1-20 [Maximum Frequency],

 

 

Operations for frequencies over 50 Hz

 

 

FU1-25 [Frequency Upper Limit],

 

 

 

 

I/O-05 [Frequency Corresponding to Max. Voltage of V1],

 

 

 

 

 

 

 

 

 

 

I/O-10 [Frequency Corresponding to Max. Current of I]

 

 

Selecting an appropriate output

 

 

FU1-20 [Maximum Frequency],

 

 

characteristics for the load

 

 

FU1-21 [Base Frequency]

 

 

 

 

 

FU1-22 [Starting Frequency],

 

 

Motor output torque adjustment

 

 

FU1-26~28 [Torque Boost],

 

 

 

 

FU1-59~60 [Stall Prevention],

 

 

 

 

 

 

 

 

 

 

FU2-30 [Rated Motor]

 

 

Output frequency limit

 

 

FU1-23~25 [Frequency Upper/Lower Limit],

 

 

 

 

I/O-01~10 [Analog Frequency Setting]

 

 

 

 

 

 

 

Motor Overheat protection

 

 

FU1-50~53 [Electronic Thermal], FU2-30 [Rated Motor]

 

 

 

 

 

I/O-12~14 [Define the Multi Function Input Terminals],

 

 

Multi step operation

 

 

I/O-20~27 [Jog, Multi Step Frequency],

 

 

 

 

 

FU1-23~25 [Frequency Upper/Lower Limit]

 

 

Jog Operation

 

 

I/O-20 [Jog Frequency]

 

 

Frequency Jump Operation

 

FU2-10~16 [Frequency Jump]

 

 

Timing the electronic brake operation

 

 

I/O-42~43 [Frequency Detection Level],

 

 

 

 

I/O-44 [Multi Function Output]

 

 

 

 

 

 

 

Displaying the rotating speed

 

 

DRV-04 [Motor Speed],

 

 

 

 

FU2-74 [Motor RPM Display Gain]

 

 

 

 

 

 

 

Function alteration prevention

 

 

FU2-94 [Parameter Lock]

 

 

Energy Saving

 

 

FU1-39 [Energy Saving]

 

 

Auto restart operation after alarm stop

 

 

FU2-27~28 [Auto Retry]

 

 

2nd motor operation

 

 

FU2-81~90 [2nd Function]

 

 

PID feedback operation

 

 

FU2-50~54 [PID Operation]

 

 

Frequency reference signal and output

 

 

I/O-01~10 [Analog Frequency Setting]

 

 

adjusting

 

 

 

 

 

 

 

 

 

Define the multi function input terminals

 

 

I/O-12~14 [Define the Multi Function Input Terminals]

 

 

Define the multi function output terminals

 

 

I/O-44 [Multi Function Output Setting]

 

 

Commercial line <-> inverter switchover

 

 

I/O-12~14 [Define the Multi Function Input Terminals],

 

 

operation

 

 

I/O-44 [Multi function Output Setting]

 

 

Frequency meter calibration

 

 

I/O-40~41 [FM Output]

 

 

 

 

 

I/O-46 [Inverter No.],

 

 

Operate by communicating with a computer

 

 

I/O-47 [communication Speed],

 

 

 

 

 

I/O-48~49 [Loss of Reference]

 

 

 

104

 