Cleveland Range inverter manual MODBUS-RTUCommunication, Parameter, Default, Max. value, Code

Models: inverter

1 119
Download 119 pages 48.5 Kb
Page 89
Image 89
value

Chapter 5 - MODBUS-RTU Communication

 

Parameter

 

 

Parameter

 

 

Description

 

 

Default

 

 

Max. value

 

 

Min. value

 

 

Unit

 

 

Note

 

 

address

 

 

Code

 

 

 

 

value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

620C

 

 

FU1 #12

 

 

DcSt value

 

50

 

200

 

0

 

1%

 

 

 

 

 

620D

 

 

FU1 #13

 

 

DcSt time

 

0

 

600

 

0

 

 

0.1sec

 

 

 

 

 

6214

 

 

FU1 #20

 

 

Max freq.

 

5000

 

40000

 

4000

 

 

0.01Hz

 

 

 

 

 

6215

 

 

FU1 #21

 

 

Base freq.

 

5000

 

 

FU1-20

 

3000

 

 

0.01Hz

 

 

 

 

 

6216

 

 

FU1 #22

 

 

Start freq.

 

10

 

1000

 

10

 

 

0.01Hz

 

 

 

 

 

6217

 

 

FU1 #23

 

 

Freq limit

 

0

 

1

 

0

 

 

 

 

 

 

 

 

6218

 

 

FU1 #24

 

 

F-limit Lo.

 

0

 

 

FU1-25

 

0

 

 

0.01Hz

 

 

 

 

 

6219

 

 

FU1 #25

 

 

F-limit Hi.

 

5000

 

 

FU1-20

 

 

FU1-24

 

 

0.01Hz

 

 

 

 

 

621A

 

 

FU1 #26

 

 

Torque boost

 

0

 

1

 

0

 

 

 

 

 

 

 

 

621B

 

 

FU1 #27

 

 

Fwd boost

 

50

 

150

 

0

 

0.1%

 

 

 

 

 

621C

 

 

FU1 #28

 

 

Rev boost

 

50

 

150

 

0

 

0.1%

 

 

 

 

 

621D

 

 

FU1 #29

 

 

V/F pattern

 

0

 

2

 

0

 

 

 

 

 

 

 

 

621E

 

 

FU1 #30

 

 

User freq. 1

 

1250

 

 

FU1-32

 

0

 

 

0.01Hz

 

 

 

 

 

621F

 

 

FU1 #31

 

 

User volt. 1

 

25

 

100

 

0

 

%

 

 

 

 

 

6220

 

 

FU1 #32

 

 

User freq. 2

 

2500

 

 

FU1-34

 

 

FU1-30

 

 

0.01Hz

 

 

 

 

 

6221

 

 

FU1 #33

 

 

User volt. 2

 

50

 

100

 

0

 

%

 

 

 

 

 

6222

 

 

FU1 #34

 

 

User freq. 3

 

3750

 

 

FU1-36

 

 

FU1-32

 

 

0.01Hz

 

 

 

 

 

6223

 

 

FU1 #35

 

 

User volt. 3

 

75

 

100

 

0

 

%

 

 

 

 

 

6224

 

 

FU1 #36

 

 

User freq. 4

 

5000

 

 

FU1-20

 

 

FU1-34

 

 

0.01Hz

 

 

 

 

 

6225

 

 

FU1 #37

 

 

User volt. 4

 

100

 

100

 

0

 

%

 

 

 

 

 

6226

 

 

FU1 #38

 

 

Volt control

 

1000

 

1100

 

40

 

%

 

 

 

 

 

6227

 

 

FU1 #39

 

 

Energy save

 

0

 

30

 

0

 

%

 

 

 

 

 

6232

 

 

FU1 #50

 

 

ETH select

 

0

 

1

 

0

 

 

 

 

 

 

 

 

6233

 

 

FU1 #51

 

 

ethperc

 

180

 

250

 

 

FU1-52

 

%

 

 

 

 

 

6234

 

 

FU1 #52

 

 

contperc

 

120

 

 

FU1-51

 

50

 

%

 

 

 

 

 

6235

 

 

FU1 #53

 

 

Motor type

 

0

 

1

 

0

 

 

 

 

 

 

 

 

6236

 

 

FU1 #54

 

 

OL level

 

150

 

250

 

30

 

%

 

 

 

 

 

6237

 

 

FU1 #55

 

 

OL time

 

100

 

300

 

0

 

 

0.1sec

 

 

 

 

 

6238

 

 

FU1 #56

 

 

OLT select

 

0

 

1

 

0

 

 

 

 

 

 

 

 

6239

 

 

FU1 #57

 

 

OLT level

 

200

 

250

 

30

 

%

 

 

 

 

 

623A

 

 

FU1 #58

 

 

OLT time

 

600

 

600

 

0

 

 

0.1sec

 

 

 

 

 

623B

 

 

FU1 #59

 

 

Stall prev.

 

0

 

7

 

0

 

 

 

 

 

 

 

 

623C

 

 

FU1 #60

 

 

Stall level

 

200

 

250

 

30

 

%

 

 

 

 

83

Page 89
Image 89
Cleveland Range inverter manual MODBUS-RTUCommunication, Parameter, Default, Max. value, Code