D-Link DES-3010FA/GA User Guide

Problem Management

Problem management includes isolating problems, quantifying the problems, and then applying the solution. When a problem is detected, the exact nature of the problem must be determined. This includes how the problem is detected, and what are the possible causes of the problem. With the problem known, the effect of the problem is recorded with all known results from the problem. Once the problem is quantified, the solution is applied. Solutions are found either in this chapter, or through customer support. If no solution is found in this chapter, contact Cus- tomer Support.

Troubleshooting Solutions

Listed below are some possible troubleshooting problems and solutions. These error messages include:

Cannot connect to management using RS-232 serial connection

Cannot connect to switch management using Telnet, HTTP, SNMP, etc.

Self-test exceeds 15 seconds

No connection is established and the port LED is on

Device is in a reboot loop

No connection and the port LED is off

Add and Edit pages do not open.

Lost password.

Problems

Possible Cause

Solution

 

 

 

Cannot connect to man-

 

Be sure the terminal emulator program is set to VT-

agement using RS-232

 

100 compatible, 9600 baud rate, no parity, 8 data bits

serial connection

 

and one stop bit

 

 

Use the included cable, or be sure that the pin-out

 

 

complies with a standard null-modem cable

Cannot connect to

 

Be sure the switch has a valid IP address, subnet

switch management

 

mask and default gateway configured

using Telnet, HTTP,

 

Check that your cable is properly connected with a

SNMP, etc.

 

valid link light, and that the port has not been dis-

 

 

abled

 

 

Ensure that your management station is plugged into

 

 

the appropriate VLAN to manage the device

 

 

If you cannot connect using Telnet or the web, the

 

 

maximum number of connections may already be

 

 

open. Please try again at a later time.

 

 

 

No response from the

Faulty serial cable

Replace the serial cable

terminal emulation soft-

Incorrect serial cable

Replace serial cable for a pin-to-pin straight/flat

ware

 

cable

 

Software settings

Reconfigure the emulation software connection set-

 

 

tings.

Response from the ter-

Faulty serial cable

Replace the serial cable

minal emulations soft-

Software settings

Reconfigure the emulation software connection set-

ware is not readable

 

tings.

 

 

 