The parameters in the above window are described as follows:

Name – the maximum length is 64 characters. This username is for password challenges (authentication). The user dialing in must supply this username in order to be allowed access to the router.

Password – this is the password associated with the above Name field.

Rem CLID – Remote Caller ID. This is the telephone number of the Remote User and is used for security. When a phone number is entered in this field, the router will make sure that the incoming call is coming from the same phone number as the one defined here. In other words, the remote user can only be calling from the telephone number defined here, otherwise the call will not be accepted. This function is disabled if the field is left blank.

Default IP – this is the IP address that will be assigned to the dial- in user when the IP Address Supply setting below is set to Default. Assigning an IP address to the remote computer ensures that the IP address does not clash with other IP addresses on your network.

IP Address Supply – this field defines how the remote user will obtain an IP address. The choices include:

Default – uses the Default IP address defined above,