Trap overview

5.3.11 Mylex traps (Mylex.mib)

MIB-OID: 1.3.6.1.4.1.231.2.10.2

This section lists Mylex traps in alphabetical order.

Trap name

ID

Meaning

Error class

 

 

 

 

mylexAdapterDied

221

Connection to a disk array

critical

 

 

controller interrupted.

 

 

 

 

 

mylexAutoRebuild

200

Automatic rebuild of a unit

critical

Started

 

has been started.

 

 

 

 

 

mylexAutoRebuild

222

Automatic rebuild of a

informational

Started2

 

system drive has been

 

 

 

started.

 

 

 

 

 

mylexBBUFound

275

Battery Backup Unit found.

informational

 

 

 

 

mylexBBUPowerLow

276

Battery Backup Unit power

critical

 

 

is low.

 

 

 

 

 

mylexBBUPowerOK

277

Battery Backup Unit power

informational

 

 

is OK.

 

 

 

 

 

mylexGamDriver

262

Incorrect version of GAM

minor

IncorrectVersion

 

driver installed.

 

 

 

 

 

mylexGamDriverMissing

261

GAM driver is either not

minor

 

 

installed or has not been

 

 

 

started.

 

 

 

 

 

mylexInitialization

231

Initialization of system drive

informational

Cancelled

 

canceled.

 

 

 

 

 

mylexInitializationDone

230

Initialization of system drive

informational

 

 

completed successfully.

 

 

 

 

 

mylexInitializationFailed

232

Initialization of system drive

major

 

 

has failed.

 

 

 

 

 

mylexInitializationStarted

229

Initialization of system drive

informational

 

 

started.

 

 

 

 

 

mylexLogicalDriveCritical

215

A logical drive is in a critical

major

 

 

state. One drive in a RAID

 

 

 

configuration has failed.

 

 

 

 

 

Table 28: Mylex traps

 

 

 

114

ServerView Event Manager

Page 114
Image 114
Fujitsu V6.00 manual Mylex traps Mylex.mib