Processing alarm entries

3.4Processing alarm entries

The following functions are available for processing the alarm entries:

Acknowledge alarms

Suppress alarms

Reset alarm suppression

Delete alarms

3.4.1Acknowledging alarms

You can acknowledge alarms that have been received.

Proceed as follows:

ÊSelect the alarm entries in the list.

ÊSelect Ack Alarm from the context menu.

The acknowledgment is indicated in the Ack column with the following icon:

3.4.2Suppressing alarms

You can suppress individual alarms of a server. This is useful if the management station is being bombarded with messages from a server that is not running correctly.

Proceed as follows:

ÊSelect the alarm entries in the list.

ÊSelect Suppress from the context menu.

You must confirm the alarm suppression. Once you have done this, all alarm entries will be deleted from the alarm list and no further alarms of this type for the server in question will be added to the list.

You can reset this setting via Filter Settings, see section "Resetting alarm suppression" on page 27.

26

ServerView Event Manager

Page 26
Image 26
Fujitsu V6.00 manual Processing alarm entries, Acknowledging alarms, Suppressing alarms