Trap overview
5.3.18 ServerControl traps (SC2.mib)
This section lists ServerControl traps in alphabetical order.
Trap name | ID | Meaning | Error class |
|
|
|
|
sc2TrapAcFail | 2040 | Mains failed in the specified | critical |
|
| cabinet. This trap occurs |
|
|
| only in storage extension |
|
|
| cabinets without UPS or |
|
|
| BBU. A server has no time |
|
|
| to send this trap. |
|
|
|
|
|
sc2TrapBatteryVoltage | 2054 | Battery is predicted to fail. | major |
Prefail |
|
|
|
|
|
|
|
sc2TrapBiosSelftest | 2005 | A critical error occurs while | critical |
Error |
| BIOS selftest. Take notice |
|
|
| of this error to clear the |
|
|
| error condition. |
|
|
|
|
|
sc2TrapBootMessage | 2102 | An error message was | major |
LogEntry |
| written into the |
|
|
| systemboard's message |
|
|
| log. This could have |
|
|
| happened when an error |
|
|
| occurred before the server |
|
|
| management agents were |
|
|
| running or any error without |
|
|
| a specific trap. See server |
|
|
| management message log |
|
|
| for detailed error |
|
|
| description. |
|
|
|
|
|
sc2TrapBootRetryCount | 2095 | This trap will be sent when a | major |
Zero |
| boot retry counter gets zero |
|
|
| on power up. |
|
|
|
|
|
Table 41: ServerControl traps (SC2.mib)
ServerView Event Manager | 139 |