Trap overview

5.3.18 ServerControl traps (SC2.mib)

MIB-OID: 1.3.6.1.4.1.231.2.10.2.2.10.20

This section lists ServerControl traps in alphabetical order.

Trap name

ID

Meaning

Error class

 

 

 

 

sc2TrapAcFail

2040

Mains failed in the specified

critical

 

 

cabinet. This trap occurs

 

 

 

only in storage extension

 

 

 

cabinets without UPS or

 

 

 

BBU. A server has no time

 

 

 

to send this trap.

 

 

 

 

 

sc2TrapBatteryVoltage

2054

Battery is predicted to fail.

major

Prefail

 

 

 

 

 

 

 

sc2TrapBiosSelftest

2005

A critical error occurs while

critical

Error

 

BIOS selftest. Take notice

 

 

 

of this error to clear the

 

 

 

error condition.

 

 

 

 

 

sc2TrapBootMessage

2102

An error message was

major

LogEntry

 

written into the

 

 

 

systemboard's message

 

 

 

log. This could have

 

 

 

happened when an error

 

 

 

occurred before the server

 

 

 

management agents were

 

 

 

running or any error without

 

 

 

a specific trap. See server

 

 

 

management message log

 

 

 

for detailed error

 

 

 

description.

 

 

 

 

 

sc2TrapBootRetryCount

2095

This trap will be sent when a

major

Zero

 

boot retry counter gets zero

 

 

 

on power up.

 

 

 

 

 

Table 41: ServerControl traps (SC2.mib)

ServerView Event Manager

139

Page 139
Image 139
Fujitsu V6.00 manual ServerControl traps SC2.mib, Trap overview