Fujitsu V6.00 manual ErrorModule

Models: V6.00

1 174
Download 174 pages 44.15 Kb
Page 36
Image 36

iRMC S2 SEL Entries and SC2 MIB Traps

Error

iRMC S2 SEL entry

Trap text

Trap

Trap name

code

 

 

no.

 

 

 

 

 

 

190017

’DIMM XY’: Memory

Memory module

2070

sc2TrapMem

 

replaced by spare

’DIMM XY’ in cabinet

 

ErrorModule

 

memory

XY of server XY had

 

Replaced

 

 

failed and was

 

 

 

 

replaced by a hot-

 

 

 

 

spare module.

 

 

 

 

 

 

 

19001A

’DIMM XY’: Memory

Memory module

2068

sc2TrapMem

 

module failed

failure is predicted

 

ErrorModule

 

predicted

for module ’DIMM

 

Prefail

 

 

XY’ in cabinet XY of

 

 

 

 

server XY.

 

 

 

 

 

 

 

19001F

Memory: redundancy

Memory

2074

sc2TrapMem

 

lost

configuration in

 

Error

 

 

cabinet XY of server

 

Redundancy

 

 

XY has lost

 

Lost

 

 

redundancy.

 

 

 

 

 

 

 

190035

’DIMM XY’: Memory

Memory module

2069

sc2Trap

 

module error

’DIMM XY’ in cabinet

 

MemError

 

 

XY of server XY is

 

ModuleFailing

190036

’DIMM XY’: Memory

 

failing. Too many

 

 

 

module failed

 

 

 

errors have

 

 

 

(disabled)

 

 

 

occurred.

 

 

 

 

 

 

 

 

 

 

 

340002

Housing opened

The front door or

2110

sc2Trap

 

 

housing of cabinet

 

Intrusion

 

 

XY was opened on

 

Assertion

 

 

server XY.

 

 

 

 

 

 

 

340003

Housing closed

The front door of

2111

sc2Trap

 

 

housing of cabinet

 

Intrusion

 

 

XY was closed on

 

Deassertion

 

 

server XY.

 

 

 

 

 

 

 

Table 4: iRMC S2 SEL entry - SC2 MIB trap