iRMC S2 SEL Entries and SC2 MIB Traps
Error | iRMC S2 SEL entry | Trap text | Trap | Trap name |
code |
|
| no. |
|
|
|
|
|
|
07000A | ’PSU XY’: Power | Temperature at | 2037 | sc2TrapPower |
| supply critical | power supply ’PSU |
| SupplyCritical |
| temperature | XY’ in cabinet XY of |
| Temperature |
|
| server XY has |
|
|
|
| reached the critical |
|
|
|
| level. |
|
|
|
|
|
|
|
07000F | ’PSU XY’: Power | Fan failure is | 2038 | sc2TrapPower |
| supply fan prefailure | predicted at power |
| SupplyFan |
|
| supply ’PSU XY’ in |
| Failure |
|
| cabinet XY of server |
| Prediction |
|
| XY. |
|
|
|
|
|
|
|
0C0004 | ’CPU XY’: CPU | Internal error (IERR) | 2082 | sc2TrapCpu |
| internal error (IERR) | occurred on CPU |
| Ierr |
|
| ’CPU XY’ in cabinet |
|
|
0C0021 | ’CPU XY’: |
|
| |
XY of server XY. |
|
| ||
| Uncorrected CPU |
|
| |
|
|
|
| |
| Machine Check |
|
|
|
| Architecture (MCA) |
|
|
|
| error |
|
|
|
|
|
|
|
|
0C0007 | ’CPU XY’: CPU clock | CPU speed at server | 2080 | sc2TrapCpu |
| automatically | XY changed to XY |
| Speed |
| throttled | percent of its |
| Changed |
|
| maximum speed. |
|
|
|
|
|
|
|
0C0017 | ’CPU XY’: CPU | CPU failure is | 2081 | sc2TrapCpu |
| failure predicted | predicted for CPU |
| Prefail |
|
| ’CPU XY’ in cabinet |
|
|
|
| XY. |
|
|
|
|
|
|
|
0C000B | ’CPU XY’: CPU | CPU ’CPU XY’ in | 2083 | sc2TrapCpu |
| disabled | cabinet XY of server |
| Disabled |
|
| XY is disabled. |
|
|
|
|
|
|
|
Table 4: iRMC S2 SEL entry - SC2 MIB trap
ServerView Event Manager | 33 |