Trap overview

 

 

 

 

Trap name

ID

Meaning

Error class

 

 

 

 

fanFailureTrap

5

The fan in the specified

major

 

 

location has failed. Replace

 

 

 

fan.

 

 

 

 

 

fanInformationTrap

6

The fan in the specified

informational

 

 

location was recovered.

 

 

 

 

 

lunFailureTrap

16

The LUN has failed and is

critical

 

 

off-line. Possible cause is

 

 

 

too many failed disk drives

 

 

 

that make up the LUN, the

 

 

 

OS can no longer

 

 

 

communicate with the LUN

 

 

 

for other reasons.

 

 

 

 

 

lunInformationTrap

19

A LUN has become optimal

informational

 

 

due to successful

 

 

 

completion of the

 

 

 

reconstruction process.

 

 

 

 

 

lunReconstructTrap

17

The LUN has started the

minor

 

 

reconstruction process but

 

 

 

is available for normal use.

 

 

 

Possible causes are an

 

 

 

available disk drive was

 

 

 

created as a spare to be

 

 

 

inserted into the set, an

 

 

 

existing spare was

 

 

 

automatically added to the

 

 

 

set for reconstruction upon

 

 

 

failure of a member disk

 

 

 

device.

 

 

 

 

 

lunReducedTrap

18

A LUN has become

major

 

 

degraded due to a member

 

 

 

disk device failure. Replace

 

 

 

the failed disk device; add a

 

 

 

spare to the system to

 

 

 

cause a reconstruct.

 

 

 

 

 

Table 37: PXRE traps

 

 

 