| Trap overview |
|
|
|
|
Trap name | ID | Meaning | Error class |
|
|
|
|
fanFailureTrap | 5 | The fan in the specified | major |
|
| location has failed. Replace |
|
|
| fan. |
|
|
|
|
|
fanInformationTrap | 6 | The fan in the specified | informational |
|
| location was recovered. |
|
|
|
|
|
lunFailureTrap | 16 | The LUN has failed and is | critical |
|
|
| |
|
| too many failed disk drives |
|
|
| that make up the LUN, the |
|
|
| OS can no longer |
|
|
| communicate with the LUN |
|
|
| for other reasons. |
|
|
|
|
|
lunInformationTrap | 19 | A LUN has become optimal | informational |
|
| due to successful |
|
|
| completion of the |
|
|
| reconstruction process. |
|
|
|
|
|
lunReconstructTrap | 17 | The LUN has started the | minor |
|
| reconstruction process but |
|
|
| is available for normal use. |
|
|
| Possible causes are an |
|
|
| available disk drive was |
|
|
| created as a spare to be |
|
|
| inserted into the set, an |
|
|
| existing spare was |
|
|
| automatically added to the |
|
|
| set for reconstruction upon |
|
|
| failure of a member disk |
|
|
| device. |
|
|
|
|
|
lunReducedTrap | 18 | A LUN has become | major |
|
| degraded due to a member |
|
|
| disk device failure. Replace |
|
|
| the failed disk device; add a |
|
|
| spare to the system to |
|
|
| cause a reconstruct. |
|
|
|
|
|
Table 37: PXRE traps |
|
|
|
ServerView Event Manager | 127 |