Macros

4.11Macros

Below is a list of macros that can be used for the forwarding of alarms (e.g. Mail, Pager).

These macros are replaced by the corresponding information about the servers which are reporting the alarm.

Name

Meaning

 

 

$_SRV

Name of the server

 

 

$_TRP

Text of the alarm message

 

 

$_TYP

Brief description of the alarm

 

 

$_IPA

IP address of the server

 

 

$_CTY

Community

 

 

$_SEV

Severity of the alarm

 

(critical, major, minor, informational, unknown)

 

 

$_TIM

Time model (format: yyyy-mm-dd-hh.mm.ss)

 

Local time schedule of the management station according to

 

which an alarm is forwarded.

 

 

$_IDN

ID number of the server

 

 

$_OMS

Name of management station

 

 

$_MIB

MIB file name of the received alarm

 

 

$_SPC

Specific number of the received alarm

 

 

$_MDL

Fujitsu REMCS ID of a hardware which is reporting the alarm

 

 

Table 16: Macros

78

ServerView Event Manager

Page 78
Image 78
Fujitsu V6.00 manual Macros