iRMC S2 SEL Entries and SC2 MIB Traps
3.7iRMC S2 SEL entries relayed as SC2 MIB traps
IThe following table applies to PRIMERGY systems manufactured in 2009 or later.
If the iRMC S2 writes an event to the System Event Log (SEL), in some cases an SNMP trap is triggered. The following table shows the correlation between the iRMC S2 entries in the SEL and the traps they trigger.
INot all iRMC S2 entries made in the SEL trigger an SNMP trap. Some trigger the same trap.
Error | iRMC S2 SEL entry | Trap text | Trap | Trap name |
code |
|
| no. |
|
|
|
|
|
|
000011 | System event log | The System Event | 2101 | sc2TrapMessa |
| (SEL) warning | Log for cabinet XY at |
| geLogWarning |
| threshold exceeded | server XY has |
|
|
|
| exceeded XY |
|
|
|
| percent of its |
|
|
|
| capacity. |
|
|
|
|
|
|
|
040000 | ’FAN XY’: Fan failed | Fan ’FAN XY’ failed | 2014 | sc2TrapFan |
|
| in cabinet XY of |
| Failed |
|
| server XY. |
|
|
|
|
|
|
|
040001 | ’FAN XY’: Fan is | Fan ’FAN XY’ was | 2010 | sc2TrapFan |
| working | added into cabinet |
| Added |
|
| XY of server XY. |
|
|
|
|
|
|
|
|
| Fan ’FAN XY’ in | 2012 | sc2TrapFanOk |
|
| cabinet XY of server |
|
|
|
| XY is working again. |
|
|
|
|
|
|
|
040002 | ’FAN XY’: Fan | Fan ’FAN XY’ will fail | 2013 | sc2TrapFan |
| prefailure | in near future in |
| Critical |
|
| cabinet XY of server |
|
|
|
| XY. |
|
|
|
|
|
|
|
Table 4: iRMC S2 SEL entry - SC2 MIB trap
30 | ServerView Event Manager |