Fujitsu V6.00 IRMC S2 SEL entries relayed as SC2 MIB traps, IRMC S2 SEL Entries and SC2 MIB Traps

Models: V6.00

1 174
Download 174 pages 44.15 Kb
Page 30
Image 30

iRMC S2 SEL Entries and SC2 MIB Traps

3.7iRMC S2 SEL entries relayed as SC2 MIB traps

IThe following table applies to PRIMERGY systems manufactured in 2009 or later.

If the iRMC S2 writes an event to the System Event Log (SEL), in some cases an SNMP trap is triggered. The following table shows the correlation between the iRMC S2 entries in the SEL and the traps they trigger.

INot all iRMC S2 entries made in the SEL trigger an SNMP trap. Some trigger the same trap.

Error

iRMC S2 SEL entry

Trap text

Trap

Trap name

code

 

 

no.

 

 

 

 

 

 

000011

System event log

The System Event

2101

sc2TrapMessa

 

(SEL) warning

Log for cabinet XY at

 

geLogWarning

 

threshold exceeded

server XY has

 

 

 

 

exceeded XY

 

 

 

 

percent of its

 

 

 

 

capacity.

 

 

 

 

 

 

 

040000

’FAN XY’: Fan failed

Fan ’FAN XY’ failed

2014

sc2TrapFan

 

 

in cabinet XY of

 

Failed

 

 

server XY.

 

 

 

 

 

 

 

040001

’FAN XY’: Fan is

Fan ’FAN XY’ was

2010

sc2TrapFan

 

working

added into cabinet

 

Added

 

 

XY of server XY.

 

 

 

 

 

 

 

 

 

Fan ’FAN XY’ in

2012

sc2TrapFanOk

 

 

cabinet XY of server

 

 

 

 

XY is working again.

 

 

 

 

 

 

 

040002

’FAN XY’: Fan

Fan ’FAN XY’ will fail

2013

sc2TrapFan

 

prefailure

in near future in

 

Critical

 

 

cabinet XY of server

 

 

 

 

XY.

 

 

 

 

 

 

 

Table 4: iRMC S2 SEL entry - SC2 MIB trap

30

ServerView Event Manager

Page 30
Image 30
Fujitsu V6.00 manual IRMC S2 SEL entries relayed as SC2 MIB traps, IRMC S2 SEL Entries and SC2 MIB Traps