iRMC S2 SEL Entries and SC2 MIB Traps

Error

iRMC S2 SEL entry

Trap text

Trap

Trap name

code

 

 

no.

 

 

 

 

 

 

070001

’PSU XY’: Power

Power supply ’PSU

2030

sc2TrapPower

 

supply OK

XY’ in cabinet XY at

 

SupplyAdded

 

 

server XY was

 

 

 

 

added.

 

 

 

 

 

 

 

 

 

Power supply ’PSU

2032

sc2TrapPower

 

 

XY’ in cabinet XY at

 

SupplyOk

 

 

server XY is working

 

 

 

 

again.

 

 

 

 

 

 

 

070002

’PSU XY’: Power

Power supply ’PSU

2034

sc2TrapPower

 

supply failed

XY’ in cabinet XY at

 

SupplyFailed

 

 

server failed.

 

 

 

 

 

 

 

 

 

Redundant power

2035

sc2Trap

 

 

supply ’PSU XY’ in

 

Redundant

 

 

cabinet XY at server

 

PowerSupply

 

 

XY failed. System

 

Failed

 

 

can become critical

 

 

 

 

if another power

 

 

 

 

supply fails.

 

 

 

 

 

 

 

070003

’PSU XY’: Redundant

AC failure in cabinet

2040

sc2TrapAcFail

 

power supply AC

XY of server XY.

 

 

 

failed

 

 

 

 

 

 

 

 

070005

Power unit: power

Power supply

2036

sc2TrapPower

 

supply redundancy

redundancy in

 

Supply

 

lost

cabinet XY at server

 

Redundancy

 

 

XY lost. System will

 

Lost

 

 

become critical if a

 

 

 

 

power supply fails.

 

 

 

 

 

 

 

070009

’PSU XY’: Redundant

DC power failure in

2041

sc2TrapDcFail

 

power supply DC

cabinet XY of server

 

 

 

failed

XY.

 

 

 

 

 

 

 

070010

’PSU XY’: Power

Fan failure at power

2039

sc2TrapPower

 

supply fan failure

supply ’PSU XY’ in

 

SupplyFan

 

 

cabinet XY of server

 

Failure

 

 

XY.

 

 

 

 

 

 

 

Table 4: iRMC S2 SEL entry - SC2 MIB trap

32

ServerView Event Manager

Page 32
Image 32
Fujitsu V6.00 manual IRMC S2 SEL entry SC2 MIB trap