iRMC S2 SEL Entries and SC2 MIB Traps
Error | iRMC S2 SEL entry | Trap text | Trap | Trap name |
code |
|
| no. |
|
|
|
|
|
|
070001 | ’PSU XY’: Power | Power supply ’PSU | 2030 | sc2TrapPower |
| supply OK | XY’ in cabinet XY at |
| SupplyAdded |
|
| server XY was |
|
|
|
| added. |
|
|
|
|
|
|
|
|
| Power supply ’PSU | 2032 | sc2TrapPower |
|
| XY’ in cabinet XY at |
| SupplyOk |
|
| server XY is working |
|
|
|
| again. |
|
|
|
|
|
|
|
070002 | ’PSU XY’: Power | Power supply ’PSU | 2034 | sc2TrapPower |
| supply failed | XY’ in cabinet XY at |
| SupplyFailed |
|
| server failed. |
|
|
|
|
|
|
|
|
| Redundant power | 2035 | sc2Trap |
|
| supply ’PSU XY’ in |
| Redundant |
|
| cabinet XY at server |
| PowerSupply |
|
| XY failed. System |
| Failed |
|
| can become critical |
|
|
|
| if another power |
|
|
|
| supply fails. |
|
|
|
|
|
|
|
070003 | ’PSU XY’: Redundant | AC failure in cabinet | 2040 | sc2TrapAcFail |
| power supply AC | XY of server XY. |
|
|
| failed |
|
|
|
|
|
|
|
|
070005 | Power unit: power | Power supply | 2036 | sc2TrapPower |
| supply redundancy | redundancy in |
| Supply |
| lost | cabinet XY at server |
| Redundancy |
|
| XY lost. System will |
| Lost |
|
| become critical if a |
|
|
|
| power supply fails. |
|
|
|
|
|
|
|
070009 | ’PSU XY’: Redundant | DC power failure in | 2041 | sc2TrapDcFail |
| power supply DC | cabinet XY of server |
|
|
| failed | XY. |
|
|
|
|
|
|
|
070010 | ’PSU XY’: Power | Fan failure at power | 2039 | sc2TrapPower |
| supply fan failure | supply ’PSU XY’ in |
| SupplyFan |
|
| cabinet XY of server |
| Failure |
|
| XY. |
|
|
|
|
|
|
|
Table 4: iRMC S2 SEL entry - SC2 MIB trap
32 | ServerView Event Manager |