iRMC S2 SEL Entries and SC2 MIB Traps
Error | iRMC S2 SEL entry | Trap text | Trap | Trap name |
code |
|
| no. |
|
|
|
|
|
|
150031 | Battery voltage ’BATT | Battery voltage | 2054 | sc2TrapBattery |
| XY’ low warning: % | ’BATT XY’ in cabinet |
| VoltagePrefail |
| Volt | XY at server XY: |
|
|
|
| Battery is predicted |
|
|
|
| to fail in near future. |
|
|
|
|
|
|
|
190003 | ’DIMM XY’ Memory: | Uncorrectable | 2065 | sc2Trap |
| Uncorrectable error | memory error at |
| Uncorrectable |
| (ECC) | module ’DIMM XY’ |
| MemError |
|
| in cabinet XY of |
| Module |
190040 | ’DIMM XY’: |
| ||
server XY. |
|
| ||
| Uncorrectable Parity |
|
| |
|
|
|
| |
| memory error |
|
|
|
|
|
|
|
|
190007 | Memory: | Uncorrectable | 2067 | sc2Trap |
| Uncorrectable error | memory error in |
| Uncorrectable |
| (ECC) | cabinet XY of server |
| MemError |
|
| XY. |
|
|
|
|
|
|
|
190008 | Correctable memory | Too many | 2071 | sc2TrapMem |
| error disabled | correctable memory |
| ErrorLogging |
|
| errors in cabinet XY |
| Disabled |
|
| at server XY. Error |
|
|
|
| logging was |
|
|
|
| disabled. If logging |
|
|
|
| was disabled and |
|
|
|
| not automatically |
|
|
|
| enabled again, you |
|
|
|
| have to reboot your |
|
|
|
| server to enable |
|
|
|
| memory error |
|
|
|
| logging again. If |
|
|
|
| logging is disabled, |
|
|
|
| prefailure detection |
|
|
|
| is also not active! |
|
|
|
|
|
|
|
Table 4: iRMC S2 SEL entry - SC2 MIB trap
ServerView Event Manager | 35 |