iRMC S2 SEL Entries and SC2 MIB Traps

Error

iRMC S2 SEL entry

Trap text

Trap

Trap name

code

 

 

no.

 

 

 

 

 

 

150031

Battery voltage ’BATT

Battery voltage

2054

sc2TrapBattery

 

XY’ low warning: %

’BATT XY’ in cabinet

 

VoltagePrefail

 

Volt

XY at server XY:

 

 

 

 

Battery is predicted

 

 

 

 

to fail in near future.

 

 

 

 

 

 

 

190003

’DIMM XY’ Memory:

Uncorrectable

2065

sc2Trap

 

Uncorrectable error

memory error at

 

Uncorrectable

 

(ECC)

module ’DIMM XY’

 

MemError

 

 

in cabinet XY of

 

Module

190040

’DIMM XY’:

 

server XY.

 

 

 

Uncorrectable Parity

 

 

 

 

 

 

 

memory error

 

 

 

 

 

 

 

 

190007

Memory:

Uncorrectable

2067

sc2Trap

 

Uncorrectable error

memory error in

 

Uncorrectable

 

(ECC)

cabinet XY of server

 

MemError

 

 

XY.

 

 

 

 

 

 

 

190008

Correctable memory

Too many

2071

sc2TrapMem

 

error disabled

correctable memory

 

ErrorLogging

 

 

errors in cabinet XY

 

Disabled

 

 

at server XY. Error

 

 

 

 

logging was

 

 

 

 

disabled. If logging

 

 

 

 

was disabled and

 

 

 

 

not automatically

 

 

 

 

enabled again, you

 

 

 

 

have to reboot your

 

 

 

 

server to enable

 

 

 

 

memory error

 

 

 

 

logging again. If

 

 

 

 

logging is disabled,

 

 

 

 

prefailure detection

 

 

 

 

is also not active!

 

 

 

 

 

 

 

Table 4: iRMC S2 SEL entry - SC2 MIB trap

ServerView Event Manager

35

Page 35
Image 35
Fujitsu V6.00 manual Ecc