Trap overview

 

 

 

 

Trap name

ID

Meaning

Error class

 

 

 

 

sc2TrapDcFail

2041

DC power failed in the

critical

 

 

specified cabinet.

 

 

 

This is the result of the

 

 

 

systems power-good

 

 

 

sensor monitoring. The

 

 

 

system stops if this error

 

 

 

occurs.

 

 

 

 

 

sc2TrapFanAdded

2010

The indicated hot-plug fan

informational

 

 

was inserted.

 

 

 

 

 

sc2TrapFanCritical

2013

The indicated fan became

major

 

 

critical.

 

 

 

 

 

sc2TrapFanFailed

2014

The indicated fan failed.

critical

 

 

 

 

sc2TrapFanOk

2012

The indicated fan is OK

informational

 

 

again.

 

 

 

 

 

sc2TrapFanRemoved

2011

The indicated hot-plug fan

informational

 

 

was removed.

 

 

 

 

 

sc2TrapIntrusionAsserti

2110

The front door or housing

major

on

 

was opened.

 

 

 

 

 

sc2TrapIntrusionChang

2112

The front door or housing

major

ed

 

was opened or closed.

 

 

 

 

 

sc2TrapIntrusionDeass

2111

The front door or housing

informational

ertion

 

was closed.

 

 

 

 

 

sc2TrapMemErrorModul

2069

A memory module failed.

major

eFailing

 

 

 

 

 

 

 

sc2TrapMemErrorModul

2068

A memory module is

major

ePrefail

 

predicted to fail (prefailure).

 

 

 

 

 

sc2TrapMemErrorModul

2070

A memory module failed

major

eReplaced

 

and was replaced by a hot-

 

 

 

spare module.

 

 

 

 

 

Table 41: ServerControl traps (SC2.mib)