Trap overview

5.3.14 PXRE traps (dec.mib)

MIB-OID: 1.3.6.1.4.1.36.2.15.21

This section lists PXRE traps in alphabetical order.

Trap name

ID

Meaning

Error class

 

 

 

 

cacheBatteryFailureTrap

7

A controller cache battery

major

 

 

has failed. Replace cache

 

 

 

battery or replenish charge.

 

 

 

 

 

cacheBattery

9

A controller cache battery

informational

InformationTrap

 

has GOOD state.

 

 

 

 

 

cacheBatteryLowTrap

8

A controller cache battery

minor

 

 

has LOW state. Replace

 

 

 

cache battery or replenish

 

 

 

charge.

 

 

 

 

 

communication

12

Communication with the

critical

FailureTrap

 

subsystem has failed. The

 

 

 

Possible causes are data

 

 

 

path interruption,

 

 

 

communication LUN failure,

 

 

 

2 or more power supplies

 

 

 

failed, 2 or more fans failed,

 

 

 

temperature over limit, both

 

 

 

controllers failed.

 

 

 

 

 

communicationInformatio

13

Communication with the

informational

nTrap

 

subsystem has recovered.

 

 

 

 

 

controllerFailureTrap

14

The Secondary Controller

major

 

 

in the subsystem has failed.

 

 

 

Replace controller. Possible

 

 

 

causes are PCMCIA

 

 

 

memory card ejected,

 

 

 

controller physically

 

 

 

removed, actual hardware

 

 

 

failure.

 

 

 

 

 

controllerInformationTrap

15

The Secondary Controller

informational

 

 

in the subsystem has

 

 

 

recovered.

 

 

 

 

 

Table 37: PXRE traps

 

 

 