Trap overview
5.3.14 PXRE traps (dec.mib)
This section lists PXRE traps in alphabetical order.
Trap name | ID | Meaning | Error class |
|
|
|
|
cacheBatteryFailureTrap | 7 | A controller cache battery | major |
|
| has failed. Replace cache |
|
|
| battery or replenish charge. |
|
|
|
|
|
cacheBattery | 9 | A controller cache battery | informational |
InformationTrap |
| has GOOD state. |
|
|
|
|
|
cacheBatteryLowTrap | 8 | A controller cache battery | minor |
|
| has LOW state. Replace |
|
|
| cache battery or replenish |
|
|
| charge. |
|
|
|
|
|
communication | 12 | Communication with the | critical |
FailureTrap |
| subsystem has failed. The |
|
|
| Possible causes are data |
|
|
| path interruption, |
|
|
| communication LUN failure, |
|
|
| 2 or more power supplies |
|
|
| failed, 2 or more fans failed, |
|
|
| temperature over limit, both |
|
|
| controllers failed. |
|
|
|
|
|
communicationInformatio | 13 | Communication with the | informational |
nTrap |
| subsystem has recovered. |
|
|
|
|
|
controllerFailureTrap | 14 | The Secondary Controller | major |
|
| in the subsystem has failed. |
|
|
| Replace controller. Possible |
|
|
| causes are PCMCIA |
|
|
| memory card ejected, |
|
|
| controller physically |
|
|
| removed, actual hardware |
|
|
| failure. |
|
|
|
|
|
controllerInformationTrap | 15 | The Secondary Controller | informational |
|
| in the subsystem has |
|
|
| recovered. |
|
|
|
|
|
Table 37: PXRE traps |
|
|
|
ServerView Event Manager | 125 |