Trap overview
Trap name | ID | Meaning | Error class |
|
|
|
|
notEnoughCabinets | 615 | The actual number of | major |
|
| storage extensions is lower |
|
|
| than number stored in the |
|
|
| configuration. |
|
|
|
|
|
powerOffTimeReached | 645 | Power off time has been | informational |
|
| reached. |
|
|
|
|
|
powerSupplyAdded | 625 | A power supply was added. | informational |
|
|
|
|
powerSupplyFailed | 626 | A power supply has failed. | major |
|
|
|
|
powerSupplyOk | 627 | The power supply is | informational |
|
| working again. |
|
|
|
|
|
powerSupplyRemoved | 624 | The power supply has been | informational |
|
| removed. |
|
|
|
|
|
powerSupplyStatus | 628 | Not enough power supplies | critical |
Critical |
| are operating. |
|
|
|
|
|
scbBBUNotdetected | 614 | A BBU is configured but no | informational |
|
| BBU was detected. |
|
|
|
|
|
scbUnconfiguredBBU | 613 | A BBU is detected but no | informational |
Detected |
| BBU was configured. |
|
|
|
|
|
scbUnconfiguredUPS | 611 | A UPS is detected but no | informational |
Detected |
| UPS was configured. |
|
|
|
|
|
scbUPSNotdetected | 612 | A UPS is configured but no | major |
|
| UPS was detected. |
|
|
|
|
|
selftestError | 609 | The server management | critical |
|
| controller has failed. |
|
|
|
|
|
selftestWarning | 608 | The server management | minor |
|
| controller has detected a |
|
|
| minor problem during its |
|
|
|
| |
|
|
|
|
serverManagement | 631 | Server Management BIOS | informational |
Disabled |
| is disabled. |
|
|
|
|
|
serverShutdown | 621 | Server has been shut down. | informational |
|
|
|
|
sieScBootCountZero | 666 | Boot retry counter gets zero | major |
|
| on power up. |
|
|
|
|
|
Table 40: ServerControl traps (SC.mib)