Fujitsu V6.00 manual Xy’ Ok

Models: V6.00

1 174
Download 174 pages 44.15 Kb
Page 34
Image 34

iRMC S2 SEL Entries and SC2 MIB Traps

Error

iRMC S2 SEL entry

Trap text

Trap

Trap name

code

 

 

no.

 

 

 

 

 

 

120030

PCI system error

The system wa

2006

sc2TrapSevere

 

(SERR): Slot 0x%1

restarted after a

 

SystemError

 

 

severe problem at

 

 

120031

PCI parity error

 

 

cabinet XY of server

 

 

 

(PERR): Slot 0%1

 

 

 

XY. See server

 

 

 

 

 

 

120034

PCI bus parity error

 

 

management

 

 

 

indicated by onboard

 

 

 

message log

 

 

 

device (PERR): Bus:

(recovery log) for

 

 

 

%1 Device: 0x%2

 

 

 

detailed information.

 

 

 

Function: 0x%3

 

 

 

 

 

 

 

 

 

 

 

120035

PCI bus system error

 

 

 

 

indicated by onboard

 

 

 

 

device (SERR): Bus:

 

 

 

 

%1 Device: 0x%2

 

 

 

 

Function: 0x%3

 

 

 

 

 

 

 

 

120042

CPU front side bus

 

 

 

 

(FSB) error

 

 

 

 

 

 

 

 

120047

Fatal NMI

 

 

 

 

 

 

 

 

150000

’Voltage XY’: Voltage

Power supply

2050

sc2Trap

 

OK

voltage ’BATT XY’ in

 

VoltageOk

 

 

cabinet XY at server

 

 

150030

Battery voltage ’BATT

 

 

 

XY’ OK

XY is within normal

 

 

 

range again.

 

 

 

 

 

 

 

 

 

 

 

150012

’Voltage XY’: Voltage

Power supply

2051

sc2Trap

 

low critical: % Volt

voltage ’Voltage XY’

 

VoltageTooLow

 

 

in cabinet XY at

 

 

150032

Battery voltage ’BATT

 

 

 

XY’ low critical: % Volt

server XY is too low.

 

 

 

 

 

 

 

150017

’Voltage XY’: Voltage

Power supply

2052

sc2Trap

 

high critical: % Volt

voltage ’Voltage XY’

 

VoltageToo

 

 

in cabinet XY at

 

High

 

 

server XY it too high.

 

 

 

 

 

 

 

Table 4: iRMC S2 SEL entry - SC2 MIB trap

34

ServerView Event Manager

Page 34
Image 34
Fujitsu V6.00 manual Xy’ Ok