4

—>REAL (INT, DINT, BCD-4, WORD)

The Convert to Real function is used to output the real value of the input data. The original data is not changed by this function.

When the function receives power flow, it performs the conversion, making the result available via output Q. The function passes power flow when power is received, unless the specified conversion would result in a value that is out of range.

It is possible for a loss of precision to occur when converting from DINT to REAL since the number of significant bits is reduced to 24.

Note

This function is only available on 350 and 360 series CPUs, Release 9 or later, or on all releases of CPU352.

_____

(enable)

(ok)

TO_

REAL

(value to be converted) —IN Q— (output parameter Q) _____

Parameters:

Parameter

Description

enable

When the function is enabled, the conversion is performed.

 

 

IN

IN contains a reference for the integer value to be converted to REAL.

 

 

ok

The ok output is energized when the function is performed without error.

 

 

Q

Q contains the REAL form of the original value in IN.

 

 

GFK-0467K

Chapter 4 Series 90-30/20/Micro Instructions Set

4-101

Page 182
Image 182
GE 90-30/20/Micro manual Real INT, DINT, BCD-4, Word