Table A-1. Instruction Timing-Continued

Function

 

 

Enabled

Disabled

Increment

Enabled

Disabled

 

Increment

 

 

 

 

 

 

 

 

 

 

 

Group

Function

350/351/36x

350/351/36x

350/351/36x

352

352

 

352

Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timers

On-Delay Timer

4

6

4

5

 

15

 

Timer

 

3

3

2

2

 

15

 

Off-Delay Timer

3

3

3

2

 

15

 

 

 

 

 

 

 

 

 

 

 

Counters

Up Counter

 

1

3

2

2

 

13

 

Down Counter

 

3

3

1

2

 

13

 

 

 

 

 

 

 

 

 

 

 

Math

Addition (INT)

 

2

0

1

0

 

13

 

Addition (DINT)

2

0

2

0

 

19

 

Addition (REAL)

52

0

33

0

 

17

 

Subtraction (INT)

2

0

1

0

 

13

 

Subtraction (DINT)

2

0

2

0

 

19

 

Subtraction (REAL)

53

0

34

0

 

17

 

Multiplication (INT)

21

0

21

0

 

13

 

Multiplication

(DINT)

24

0

24

0

 

19

 

Multiplication

(REAL)

68

1

38

1

 

17

 

Division (INT)

 

22

0

22

0

 

13

 

Division (DINT),

25

0

25

0

 

19

 

Division (REAL)

82

2

36

2

 

17

 

Modulo Division (INT)

21

0

21

0

 

13

 

Modulo Div (DINT)

25

0

25

0

 

19

 

Square Root (INT)

42

1

41

1

 

10

 

Square Root (DINT)

70

0

70

0

 

13

 

Square Root (REAL)

137

0

35

0

 

11

Trigonometric

SIN (REAL)

 

360

0

32

0

 

11

 

COS (REAL)

 

319

0

29

0

 

11

 

TAN (REAL)

 

510

1

32

1

 

11

 

ASIN (REAL)

 

440

0

45

0

 

11

 

ACOS (REAL)

 

683

0

63

0

 

11

 

ATAN (REAL)

 

264

1

33

1

 

11

Logarithmic

LOG (REAL)

 

469

0

32

0

 

11

 

LN (REAL)

 

437

0

32

0

 

11

Exponential

EXP

 

639

0

42

0

 

11

 

EXPT

 

89

1

54

1

 

17

Radian Conversion

Convert RAD to DEG

65

1

32

1

 

11

 

Convert DEG to RAD

59

0

 

32

0

 

 

11

 

 

 

 

 

 

 

 

 

 

Notes: 1. Time (in microseconds) is based on Release 7 of Logicmaster 90-30/20/Micro software for Model 351 and 352

CPUs.

 

2.For table functions, increment is in units of length specified.; for bit operation functions, microseconds/bit.; for data move functions, microseconds/number of bits or words.

3.Enabled time for single length units of type %R, %AI, and %AQ.

4.COMMREQ time has been measured between CPU and HSC.

5.DOIO is the time to output values to discrete output module.

6.Where there is more than one possible case, the time indicated above represents the worst possible case.

A-6

Series 90-30/20/Micro Programmable Controllers Reference Manual–September 1998

GFK-0467K

Page 272
Image 272
GE 90-30/20/Micro manual Group Function