4

Example:

In the following example, when %M0125 transitions on, the programmer communications window is enabled and assigned a value of 25 ms. The parameter block is in memory location %R5051.

%I0001%M0125 —— —————————————————————————————————————————————————————————————————()—

 

 

 

 

 

_____

 

_____

 

%M0125

%T0002

—— ———MOVE_———————————————————

SVC_—————————————————————————————( )—

INT

REQ

 

 

CONST —IN

Q— %R5051

CONST —FNC

 

+00025

LEN

00003

 

0001

 

_____

%R5051—PARM

 

 

 

_____

 

To disable the programmer communications window, use Service Request 3 to assign a value of zero (0). In this example, when %M0126 transitions on, the programmer communications window is enabled and assigned a value of 0 ms. The parameter block is in memory location %R5051.

%I0002%M0126 —— —————————————————————————————————————————————————————————————————()—

 

 

 

 

 

_____

 

_____

 

%M0126

%T0002

—— ———MOVE_———————————————————

SVC_—————————————————————————————( )—

INT

REQ

 

 

CONST —IN

Q— %R5051

CONST —FNC

 

+00000

LEN

00003

 

0001

 

_____

%R5051—PARM

 

 

 

_____

 

4-140

Series 90-30/20/Micro Programmable Controllers Reference Manual–September 1998

GFK-0467K

Page 221
Image 221