RC3000 Antenna Controller

Chapter 3

Detailed Operation

3.2.2.9 Track

The optional TRACK mode may be entered via the STORE or RECALL modes if the selected satellite has been described as having a inclined orbit.

Details of TRACK mode are available in the separate appendix TRK describing inclined orbit tracking. The following descriptions give an overview of how tracking is performed.

TRACKING INCLINED ORBIT SATELLITES. The RC3000 tracking algorithm can be divided into three distinct stages - STEP_TRACK, MEMORY_TRACK, and SEARCH.

AZIM: 31561

SIG:735(C)

 

TRACK

ELEV:

11060

SAT:BRASIL

A1

 

POL:

8.2

STEP:PEAKING

AGC

JOGGING ANTENNA TO FIND MAXIMUM SIGNAL

In STEP_TRACK, the controller periodically peaks on the receiver' signal strength by jogging the antenna. The time and position are recorded in a track table maintained in the controller’s non-volatile memory. The interval between peakups is determined by antenna beamwidth (determined from antenna size and frequency band), satellite inclination and a user specified maximum allowable error (in dB). When a track table entry exists for the current sidereal time, STEP_TRACK switches to

MEMORY_TRACK.

In MEMORY_TRACK, the controller smoothly moves the antenna to azimuth and elevation positions derived from entries in the track table. The time between movements is determined by the same factors which govern the time between peakup operations in STEP_TRACK. By increasing the maximum allowable error, antenna movements can be performed less frequently. In MEMORY_TRACK, the accuracy of the track table is monitored by periodically peaking up on the receiver’s signal strength. If the error exceeds a level set by the user, all entries in the track table are flagged for update.

TRACK_SEARCH is entered when the satellite signal has been lost. The RC3000 utilizes Intelli-Search, an efficient search algorithm that minimizes errors associated with traditional box searches and frees the user from having to update vague search window parameters. This scheme accounts for the specific mount geometry, calculates the nominal trajectory for the satellite, and then searches in an area that coincides with the satellite's expected path. When the satellite is located, the controller re-enters the STEP_TRACK mode.

3.2.2.10 Remote

In REMOTE mode the controller only responds to commands received via the built-in RS-422/232 serial port. REMOTE mode can only become active if the Remote Mode Enable CONFIG item is enabled. If REMOTE mode is enabled, it can become active either in response to receipt of a valid command from the PC. Note that TRACK mode can process certain commands received via the serial port. The RS-422 communication protocol, interface specification and the RC3000 command set is found in Appendix REM.

The REMOTE mode screen is similar to the MANUAL mode screen. Only the MODE key is active when REMOTE mode is active.

90

Page 98
Image 98
HP RC3000 manual Track, Remote, Memorytrack