HP RC3000 manual Settings, 0RESET Drive, Autopeak Autopeak 0DISABLE 1ENABLE 2+PEAK

Models: RC3000

1 143
Download 143 pages 35.5 Kb
Page 97
Image 97

RC3000 Antenna Controller

Chapter 3

Detailed Operation

3.2.2.8 Settings

The SETTINGS mode provides a way to change the operational characteristics of the RC3000 without having to go to the configuration group of screens. It also provides a way to reset a drive error without going to the DRIVE RESET maintenance screen.

1-AUTOPEAK:OFF

SETTINGS

2- AP SIG:SS1

 

 

<0>RESET DRIVE

<1-2>CHANGE SETTING

<MODE>MENU

<0>RESET DRIVE

This selection is only available if an azimuth, elevation or polarization drive error (jam or runaway) is active. Selecting 0 will attempt to clear the error.

1-AUTOPEAK:

AUTOPEAK <0>DISABLE <1>ENABLE <2>+PEAK

Selection 0 allows the user to disable the autopeak function (OFF).

Selection 1 allows the user to turn the basic autopeak function on (ON).

Selection 2 allows the user to enable the terminal peakup function (ON+) described in 3.2.2.3.5. NOTE:

Verify that the required conditions for terminal peakup as described in 3.2.2.3.5 are present before selecting this option.

2-AP SIG:

SIGNAL SOURCE <1>RF <2>SS1 <3>SS2

Selection 2 allows the user to change the signal source that will be used with the autopeak function.

89

Page 97
Image 97
HP RC3000 manual Settings, 0RESET Drive, Autopeak Autopeak 0DISABLE 1ENABLE 2+PEAK, AP SIG Signal Source 1RF 2SS1 3SS2