RC3000 Antenna Controller | Chapter 3 | Detailed Operation |
3.2.2.8 Settings
The SETTINGS mode provides a way to change the operational characteristics of the RC3000 without having to go to the configuration group of screens. It also provides a way to reset a drive error without going to the DRIVE RESET maintenance screen.
SETTINGS | |
2- AP SIG:SS1 |
|
| <0>RESET DRIVE |
<MODE>MENU |
<0>RESET DRIVE
This selection is only available if an azimuth, elevation or polarization drive error (jam or runaway) is active. Selecting 0 will attempt to clear the error.
1-AUTOPEAK:
AUTOPEAK <0>DISABLE <1>ENABLE <2>+PEAK
Selection 0 allows the user to disable the autopeak function (OFF).
Selection 1 allows the user to turn the basic autopeak function on (ON).
Selection 2 allows the user to enable the terminal peakup function (ON+) described in 3.2.2.3.5. NOTE:
Verify that the required conditions for terminal peakup as described in 3.2.2.3.5 are present before selecting this option.
2-AP SIG:
SIGNAL SOURCE <1>RF <2>SS1 <3>SS2
Selection 2 allows the user to change the signal source that will be used with the autopeak function.
89